  1. jaskamakkara

    What load defines pile failure?

    This is likely correct. Deformation generally constitutes a servicability limit state for the structure and these are generally down to the client requirements, but your local codes may impose upper limits that apply to all projects.
  2. jaskamakkara

    Double Channel Section Spreader Beam with Combined Axial Compression and Moment

    Just thought I'd throw something in - are you planning to hot-dip galvanise this beam? Ignore this comment if not, but if you are then the detail of welding the battens to top top and bottom flanges of the channels is not a particularly good one. Moisture can get trapped in there and get...
  3. jaskamakkara

    Bulging of CFT walls

    Hi guys, sorry for not responding earlier my email notifications were going to junk for some reason. I guess water entry is a possibility, there are some weird connections at the top of the columns and it's possible a weld or two is missing or incomplete, leaving some space for water to get in...
  4. jaskamakkara

    Bulging of CFT walls

    Thanks for the input, guys. Yes, I agree that this doesn't seem to concerning and it doesn't look like anything is buckling. I think the column is rotating a little and it gives the impression that it is bulging - I think I'll go back on site with a nice long straight edge and have a look...
  5. jaskamakkara

    Bulging of CFT walls

    Hi guys, just wondering what you make of this concrete-filled tube that we found during a frame inspection. It looks like all the side of the column are bulging - indeed it looks like the concrete socle at the base is restraining the deformation which is why some concrete is spalling off. At the...
  6. jaskamakkara

    Modelling closely spaced supports in FEM package

    @bones206 yeah I had that idea too, think I'll make that model just out of interest and see what happens.
  7. jaskamakkara

    Modelling closely spaced supports in FEM package

    Thanks for the replies, everyone. And yes, I think you have confirmed my suspicions that I should just condense these double supports into singles, as jayrod said there is likely enough give in the joints that the loads are shared. JoshPlum, I agree that if I could put in some springs instead of...
  8. jaskamakkara

    Modelling closely spaced supports in FEM package

    Hi everyone, I am checking a steel crane beam in an old theater. It is about 21m long and is supported in 3 intermediate points for 4 continuous spans of approx 5m. It is connected at these points to perpendicularly spanning concrete beams by way of channel sections, welded vertically to the...
  9. jaskamakkara

    Torsional column restraint at bottom of haunch in portal frame

    I am detailing a portal frame that has HEB260 columns and IPE600 rafters. I am trying to detail the proper restraint to the columns at the level of the base of the haunch. I am using SCI documents P397, P399, and P252 (which all pertain to portal frame design) as references but I have some...
  10. jaskamakkara

    Profis user, Hilti Specifier, NO MORE

    It's just been replaced with Profis Engineering (profisengineering.hilti.com), it is still free for the basic version which appears to have the same functionality as the old version of Profis.
  11. jaskamakkara

    The "Newman Lug"

    I would say that welding washers down over the anchors after installation is best, also means that you can leave nice big holes in the plates for installation tolerances. Just have to be careful with any shear loads that might be incident during construction (i.e. before they've managed to weld...
  12. jaskamakkara

    Checking buckling of a beam modelled with 2d elements in FEM

    Hi guys, I have a beam that is installed already but needs to have the flanges on one side of a 500mm long section of it removed to make room for a pipe. I am using SCIA Engineer FEM package and I would like to check that there are no adverse buckling effects etc from this flange removal...
  13. jaskamakkara

    Bolt Head Pull Through in Steel

    Yes actually the Eurocode has the same formula:
  14. jaskamakkara

    Transverse Reinforcement - One Way In-site Concrete Slab to EC2

    Here is the same requirement lifted from the Eurocode (EN 1992-1-1): §7.3.3 states the following: However, 7.3.1(3) states: So if you have problems with shrinkage cracks then you might need to add more steel as hokie says. But there is no "rule of thumb" for calculating such...
  15. jaskamakkara

    Slanted Stirrups - Beam Shear Reinforcment

    Not really sure what you're asking, but if it's to do with the angle of stirrups in RC members then the equations for shear resistance (crushing of concrete struts, and yielding of shear reinforcement) take into account the angle of the links:
  16. jaskamakkara

    Transverse Reinforcement - One Way In-site Concrete Slab to EC2

    According to How to Design Concrete Structures using Eurocode 2, The Concrete Centre:
  17. jaskamakkara

    Steel protection against corrosion

    You could check these documents out for advice, they pertain to galvanised rebar but the advice should apply mostly to your case. https://galvanizeit.org/uploads/publications/Galvanized_Rebar_Concrete_Investment.pdf...
  18. jaskamakkara

    Steel section for roof beams in warehouse

    Well I sections are generally used for portal frame design since wind loading is pretty dominant and you need the section depth to resist the large in-plane bending moments. LTB of the columns and rafters becomes a problem with these sections so restraint is usually provided by the roof purlins...
  19. jaskamakkara

    Bolt Head Pull Through in Steel

    I think you can just use the equations for resistances of T-stubs? SCI document P398 (which provides an easier to read summary of EN 1993-1-8) covers this in detail and provides illustrations. You can check for all 3 modes of failure: Flange yielding, bolt + flange failure, and bolt failure. If...
  20. jaskamakkara

    Rebar butt welded to end plate - full strength?

    The strength of a full penetration butt weld is that of the weaker connected member, provided the properties of the consumable are better than those of the parent material. Refer to §4.7.1 of EN 1993-1-8 if you have access to Eurocodes.