  1. CD_UK

    Cetop Valve Not Changing Motor Direction

    Thanks. I'll give that a try when I'm in the workshop. Still very odd how two valves (of different brands even more so), are behaving this way. Will be very coincidental if I find the incorrect spool has been installed in both.
  2. CD_UK

    Cetop Valve Not Changing Motor Direction

    Thanks very much for the replies. Coils are DC, and operating correctly. Manually overriding them achieves the same result, so it's not a coil issue. The coil plugs have led indicators, and are receiving power independently, (i.e. both are not accidentally being powered simultaneously)...
  3. CD_UK

    Cetop Valve Not Changing Motor Direction

    Very simple circuit - Cetop 3 valve on a single manifold with PRV, feeding a reversible gear motor. Whichever solenoid is activated, the motor turns in the same direction. If I swap the hoses over, the motor does change direction, (although the valve still does not reverse the flow when the...
  4. CD_UK

    Series- parallel motor connection with a simple dcv

    I think your objective is to connect both motors together to perhaps drive a twin roller feed system. If so, connect valve A to first motor A, then connect first motor B to second motor A, then connect second motor B to valve B. Output from the valve flows through the first motor, feeding the...
  5. CD_UK

    Spool Valve Type

    Looking to replace an unsuitable spool valve on an excavator. 6-bank required, with ability to control multiple banks simultaneously. Can anyone confirm which type I should be looking for? Something with a parallel circuit configuration? Or is there more to consider? My guess is that without...