  1. Adnan.B

    power plant performance

    Hi, I am looking for a reliable software for performance test on steam turbine, boiler, surface condenser... any advise please? thanks.
  2. Adnan.B

    Boiler tubes storage

    Hello All, we have amount of boiler tube walls stored, the tubes are kept indoors and away of water ingress. I am looking for recommendations, standards or technical practices for boiler tubes prolonged safe storage. thank you.
  3. Adnan.B

    PSV butt weld inlet #2500 - Nozzle Seat Removal

    a portable lathe machine is available for rectifying the seat, the welding is another challenge indeed since we are not sure about the stellite grade.
  4. Adnan.B

    PSV butt weld inlet #2500 - Nozzle Seat Removal

    Thank you so much for the clarification, this was very very helpful [2thumbsup]
  5. Adnan.B

    PSV butt weld inlet #2500 - Nozzle Seat Removal

    here is the picture of the safety valve nozzle subject for maintenance. unlike the previous picture of the same exact type the nozzle is still attached. https://files.engineering.com/getfile.aspx?folder=7f8da7b8-78fb-4e0c-96c2-23a1f6ee45ad&file=3.jpg
  6. Adnan.B

    PSV butt weld inlet #2500 - Nozzle Seat Removal

    Please check out the attached picture, there is some safety valves i found scrapped and one of them surprized me with the nozzle seat unscrewed this is what makes me wonder if there is some kind of special tool to remove the nozzle...
  7. Adnan.B

    PSV butt weld inlet #2500 - Nozzle Seat Removal

    Hello Every One, we have set of PSV's installed on Steam drum. #2500 type 1762, is there a way we can remove and replace only the nozzle seat instead of cutting off the PSV butt welded flange. thank you so much.
  8. Adnan.B

    Boiler Water Chemistry (high chlorine level)

    Dear EdStainless, our research aims to verify if we contain O2 and Ph what would be the chlorine effect? I am referring to chlorine cl and not chloride cl- thank you so much for your reply and your kind follow up.
  9. Adnan.B

    Boiler Water Chemistry (high chlorine level)

    Hello Ashtree, it is chlorine. thanks and best regards.
  10. Adnan.B

    Boiler Water Chemistry (high chlorine level)

    Dear Experts, we are experiencing high chlorine levels in one of our units (0.3ppm) in the boiler drum, the boiler pressure is 150 bar and we are on maximum blow down. no chlorine is detected in feed water so we are doubting a condenser tube leak, the PH is fine (9.2) and the conductivity is...