  1. Da CnS Engr

    Structural Frame Analysis

    Hi everyone, Attached is photo of a structural frame. Can anyone help to resolve R1, R2, R3 and R4 in terms of "P" and "L"? From my own understanding: 1. P = R3 + R4 2. Since the frame should stay static, the tilting force from P would result in R1 to be a downward force. I did my own...
  2. Da CnS Engr

    Water Reticulation Analysis using EPANET

    Hi everyone, I'm new to EPANET and am trying to run a analysis for a project. Attached are the pipeline layout and EPANET file. Parameters 1. 159 single residential units, 3.3m roof height, 1500 litres/unit/day 2. With fire hydrant 3. Tapping from existing 400mm DI pipe, min. pressure of 10m...
  3. Da CnS Engr

    Tide Level vs. Flood Level

    Thanks for all the replies, but I'm having a hard time trying to understand all of it.. Can anyone explain in simpler terms? Maybe in some graphical sketch? Thanks.
  4. Da CnS Engr

    Tide Level vs. Flood Level

    Hi everyone, Does anyone know the difference between Highest Tide Level & Highest Flood Level? I've tried to find information regarding this but to no avail..
  5. Da CnS Engr

    Earth Drain side slope

    Attached is the typical detail drawinghttps://files.engineering.com/getfile.aspx?folder=ab02318e-7cb4-4952-912a-00f24d81a0f4&file=Typical_Swale__with_Gabion_Detail.JPG
  6. Da CnS Engr

    Earth Drain side slope

    @TigerGuy, yes I do have enough room for tiebacks but dont think its feasible in terms of cost, the earth drain/swale is approx. 1000 metres long. @1503-44, do you know how to check the capacity?
  7. Da CnS Engr

    Earth Drain side slope

    Yes I'm aware of that.. but I'm pretty limited on the width thats why.. How about a 1:1.5 slope? Can the gabion hold it?
  8. Da CnS Engr

    Earth Drain side slope

    Hi all, I have an earth drain constrained to a size of 2.5m top width, 2m bottom width, 1.9m height, which would give the side slope 1:0.13 (H:V), can I reinforce the side slopes with gabion mattress? Or any other types of lateral reinforcements? If not, what is the limit of the side slope...
  9. Da CnS Engr

    Water Pipe Pressure

    @jimstructures, Then what would the pressure be? Do you mind to elaborate more? THanks
  10. Da CnS Engr

    Water Pipe Pressure

    Hi Everyone, I have a development where either side of the water pressure from the pipeline is not enough, say if I tap it from both points, does it mean I would get a combined higher pressure? e.g. Pressure A + Pressure B would meet and result in a higher Pressure A+B Pls refer to attached...