  1. abdallah hamdan

    how to increase footing thickness?

    How to add shear reinforcement do you have any photo or detail ? and if i want to make a footing on top of footing what is the bearing capacity that i must design the top footing for ? I saw many bearing capacity equations for concrete and can’t understand how bearing failure is going to happen...
  2. abdallah hamdan

    how to increase footing thickness?

    is it possible to add a footing on top of the existing one, which will do its job to overcome one-way and two-way shear failure, while the existing footing will transfer the load to the soil safely?
  3. abdallah hamdan

    how to increase footing thickness?

    Maybe if the concrete strength is higher than required would help , but the concrete strength always came between 1.05-1.15 from required strength, that increase did not help Can i make column capital or a footing increase in thickness , this is the question, it will not break ? As Its poured...
  4. abdallah hamdan

    how to increase footing thickness?

    The footing is not small ,2.8x2.8 m , we are forward to demolish and replace but discussing if the third solution can be done and how
  5. abdallah hamdan

    how to increase footing thickness?

    demolish and replace is the first solution but we need more time and a cost-effective solution, i have multiple suggestions that you mentioned but 1-increasing the area of footing or the column to the maximum size we can does not solve the problem from the designer's perspective unless we...
  6. abdallah hamdan

    how to increase footing thickness?

    the columns are concrete, making the column bigger does not solve the situation, because of one-way shear, its more than the footing capacity.
  7. abdallah hamdan

    how to increase footing thickness?

    Hello everyone, I have a Footing that was poured at 55 cm thickness, 15 cm lower than required (70 cm), punching shear failure will occur, How is it possible to increase the thickness of the footing? note that the footing was poured recently, and no work has been done on the column necks any...
  8. abdallah hamdan

    Structural design of staircase with split between steps

    it's a concrete stair, similar to this but it connected in the end to an RC wall (no free end), my confusion about the middle stair #6, it will cut the connection between the bars HTURKAK, Sorry for the misunderstandings and confusion, the stair on the other side is connected with the slab but...
  9. abdallah hamdan

    Structural design of staircase with split between steps

    I want to design a staircase with a split between the staircase steps, shown in the attachments (step number 6), Do you have any ideas or any explanation of how to model and design such a staircase? thanks in advance.
  10. abdallah hamdan

    design a step wall footing

    During the excavation process for a new building consisting of 6 floors, a footing was found at a level other than all the bases due to the presence of swollen soil that was removed under it, the rock layer has been reached. the footing for the retaining wall that connects two separate footings...
  11. abdallah hamdan

    torsional irregularity and eccentricity checks for structure with basement wall

    thank you HTURKAK for your response, I can't shift the retaining wall, it is located in a 2B zone with a Peak Ground Acceleration of 0.2g, and the soil profile is (SB) - Rock
  12. abdallah hamdan

    torsional irregularity and eccentricity checks for structure with basement wall

    Thank you for reply , Is it possible to separate the retaining walls from the building in certain ways during the work process? To make it just work as retaining wall
  13. abdallah hamdan

    torsional irregularity and eccentricity checks for structure with basement wall

    hello everyone, I'm making a torsional irregularity and eccentricity checks in a building with retaining-basement walls, when I model these walls, which are existed on the basement floor and ground floor, the building will have extreme torsional irregularity and eccentricity of more than 15%...
  14. abdallah hamdan

    seismic design used period and extreme torsional irregularity in a residential building

    here are the first 3 mode shapes, another question, can I use response spectrum analysis when the first mode is torsional?
  15. abdallah hamdan

    seismic design used period and extreme torsional irregularity in a residential building

    while designing a 7-story residential building, Etabs calculated the fundamental period as 1.85, and the approximated Period Ta was 0.53, the building is located in seismic zone 2B with Z=0.2g, and the period used for calculating base shear was 1.4 Ta which is 0.74, isn't the used period far...
  16. abdallah hamdan

    Searching to find best way to design footings

    I have a quesion about proper model, analyze and design using etabs , i have no clear way to assign partial fixity for column and shear wall base , according to BS 5950 , which shown in the figure , it depents on the rigidity of the connection between member and footing , and found no way to...
  17. abdallah hamdan

    base joints modeling for RCC structures

    while training to design a 10-story building, I asked many engineers about base joints for columns and shear walls, some said that joints considered as pinned are safe and more economic, but, in my opinion, the lateral load will cause a moment at the base that I should design for, any ideas...
  18. abdallah hamdan

    fixed and pinned supports

    I have reached to point and I think it's true these are details for fixed support based on "SP 34", and these are similar to the moment-resisting frame joint details so if I want to assign fixed support between column and beam I will provide this details in the design, thanks all
  19. abdallah hamdan

    fixed and pinned supports

    ok then, is there any detail to ensure a fixed joint or any calculation method?
  20. abdallah hamdan

    Vertical Seismic load criteria ASCE7/AISC

    ASCE 7-16 The vertical seismic load effect, Ev, is permitted to be taken as zero for either of the following conditions: a. In Eqs. (12.4-1), (12.4-2), (12.4-5), and (12.4-6) for structures assigned to Seismic Design Category B. b. In Eq. (12.4-2) where determining demands on the soil–structure...