Hi,
I'm trying to simulate blood flow through healthy internal carotid artery, including movement of arterial wall. I'm using co-simulation in Abaqus. My artery is modeles as straight tube with wall modeled as shell (i tried both with elastic and hyperelastic materials). I initially applied real...
Thank you all for the replies. I managed to mesh my geometry using virtual topology. However, when I run simulation at some point I'm getting an error that some elements (one or more, depending on mesh size) are severly distorted. I've noticed that such error appears in when stent gets into...
Hi,