Apologies,
The rule works, I had CounterBore parameter as "Counterbore" (with b instead of B). Now it works fine, but would like to have a Counterbore hole as shown above instead of a hole with a bottom angle.
Regards,
Thomas
Thank you again,
I tried the rule above as you mentioned, but it doesn't seem to do anything between when changing the parameter from clearance to counterbore or vice-versa.
This is what I would like to achieve, change from simple hole type to counterbore type
Regards,
Thomas
Thanks for your reply LWolf,
Unfortunately I just started using the Knowledgeware feature in CATIA, mainly Knoledge Advisor so I'm new to this. I noticed there is also Knowledge Expert and found where your print screen is coming from. I tried bringing your example into Advisor without success...
Hello all,
I am trying to change the hole type using a parameter with values CLEARANCE and COUNTERBORE. The result should be a simple hole with a given diameter when CLEARANCE is selected and then change the hole type from simple to Counterbore if COUNTERBORE is selected.
My first action was...