Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. isidor_

    STM - Wall on wall detail

    This is interesting as I was looking into this recently! I have some assorted thoughts about the subject so here we go: The provisions that OP alludes to are the image below, for the given indata (loaded area 0,2m*0,2m and 0,2m perpendicular wall below supporting) the compressive stress can be...
  2. isidor_

    Strengthening of existing steel beam under load

    Yes, now that I "know better" that the beams should be somewhat unloaded before strengthening them the problem has boiled down to how to unload them prior to strengthening. Thanks for the inspirational images! It looks very neat and is somewhat to the point I am thinking I guess the...
  3. isidor_

    Strengthening of existing steel beam under load

    About 10 beams There is some ventilation and electrical "trays" /"ladders" close below some of the lower flanges. But regardless of methods these will need to be moved -(temporarily at least) to access and reinforce from below. I'll have to check with the client, but with that said, maybe 0,5m...
  4. isidor_

    Strengthening of existing steel beam under load

    Thanks for the suggestion! It seems like a smart thing to do, but I am not sure how you mean, could you post an image or link that explains it more? It would be greatly appreciated! My guess is that you mean something like the suggestion that I posted further up in the thread, but instead of...
  5. isidor_

    Strengthening of existing steel beam under load

    Post tensining sounds like a good option in theory but as you say it is more complex to verify, among other issures relaxsation of the tension rod, load application points, ensuring that there is space for a jack that can tension the rods. Adding more steel is simpler in terms of calculating it...
  6. isidor_

    Strengthening of existing steel beam under load

    Both of them effect the stiffness (second moment of inertia) since the the formula is I = bh^3/12+A*e^2 adding more material at the bottom flange will add material far from the geometrical centroid. Prestressing cables have a yield strength of about 1500MPa, and i could just use more to achieve...
  7. isidor_

    Strengthening of existing steel beam under load

    I am controlling the capacity of some existing beams in a structure for new loads. The beams are welded I sections, ~13m long, simply supported and it looks as if they will need reinforcing. Some restrictions, limitations and other info New columns cannot be added to reduce the span length...
  8. isidor_

    Lateral load structure within building

    Okay thanks for the input! That is how i was planning to use it since I dont find anything else. It is annoying that EC is not more explicit in some aspects, such as this.. Regarding the openings, I assume you are referring to this section in EC1991-1-4 7.2.9: (3) Where an external opening...
  9. isidor_

    Lateral load structure within building

    Yes if there is a risk of accidental load (ex. forklift driving into it) that should be accounted for. Regarding the interior windload, I am somewhat unsure if it only affects the "outer shell" of the main building or if it can be assumed to affect all of the interior surfaces, such as the...
  10. isidor_

    Lateral load structure within building

    The 5psf=0.2394013 kPa (according to google) is close to the interior windload (7.2.9 (6) NOTE 2 -> cpi=0.3 multiplied by the exterior wind preasure qp(z)=~1.0kN/m2, 1.0*0.3 = 0.3kN/m^2) which I thought about using on the surfaces, so that seems like a good approximation.
  11. isidor_

    Lateral load structure within building

    There are no seismic loads where i am located. Using a fraction of the dead+live load is an option, but it feels abit arbitrary, but is ofc an option. Engineering judgement should always be used to judge if something is reasonable or not. But the question is regarding code compliant lateral load...
  12. isidor_

    Lateral load structure within building

    Hi, (Eurocode applies where i work) Say i have a large building (large industrial building) and within it a smaller structure shall be built. How is the lateral load calculated for a structure within a building? There is ofcourse the unintended inclination that will affect the new smaller...
  13. isidor_

    Footing on bedrock, rotational stiffness / degree of fixity

    Stellar replies! Didn't think I got any because the email notifications ended up in the junk mail folder -.- EireChch The horizontal force I have is about 50kN,whilst the (vertical) dead load is 5MN and the footings will be cast in holes in the rock so sliding should not be an issue according...
  14. isidor_

    Footing on bedrock, rotational stiffness / degree of fixity

    Hi, I hope my first post ends up in the correct forum, I tried to search for relevant post to this subject. (I am located in Europe so Eurocode applies for this) I have been tasked with the design of the foundation for a structure. It will be braced against horizontal load by fixed concrete...

Part and Inventory Search