  1. Avi_Weld

    Addition of PWHT

    IS this a NCR? YES, As you are applying an PWHT on an non-PWHT PQR this is against ASME Sec IX QW-407.1 irrespective of the Building Code this is a clear violation. Does the 4th WPS have to be requalified in order to rectify as per ASME IX? YES, ASME Sec IX QW-407.1 is an essential parameter...
  2. Avi_Weld

    PWHT Temp range

    Hello All, I have a PQR with 635 deg C PWHT temp for 1 hour/inch Soak for P No. 1 material Can I use this to write a WPS with 600 deg C soak temp for 90 Mins soak time. with supplementary impact test required?
  3. Avi_Weld

    Minimum Base Metal Range

    Hi All, I have a PQR as follows: Base metal thickness: 20mm GTAW deposit: 6mm SMAW deposit: 14mm if i write a WPS for GTAW what base metal thickness do i use and WHY?
  4. Avi_Weld

    Tube to Tubesheet welding

    Thanks for the response all. Impact test requirement came as client is given operating temp at -15 Deg C. Since it is clear that invoking QW-193 will not get us impact test. I can proceed with the same.
  5. Avi_Weld

    Tube to Tubesheet welding

    Hello All, I Have a question regarding the Impact test requirement for Tube tubesheet welding. Since ASME gives us permission to Combines PQR, i was curious to know if i can combine a butt weld PQR with impact test as supporting to a Tube tubesheet welding PQR for a WPS for Tube to tubesheet...