Thank you. we have 20 bulkheads and 20 compartments in outermost. Yes, as you suggested, somewhat our proposal initially but the consultant reduce number of bulkheads to only 8 for the 2nd ring from their design check. But since there is very little text on this, guess it will do.
Regards
Thank you. Hopefully adding bulkheads adds to overall stiffness that reduces localised high stress and prevent weld crack. We also will check that the roof legs don't touch the bottom plate during operation.
Thank you. It is a 60m dia.tank. It has 6 rings of approx. 5.9m each and 3m for the centre ring. Tank with 19 bulkheads in the outermost (6th ring) and none for the rest. What would be the basis for adding bulkheads for the other rings?