While modelling I also thought that I might be using wrong BCs. In the paper it is written "One end of the specimen was fixed, and the displacement was set at the other end with an amplitude of 2 mm/min". I am not quite understanding it. And for material properties I have only specified elastic...
I'm performing a creep analysis on a dogbone specimen made of SS-304. I am following this paper Correlation Analysis of Established Creep Failure Models through Computational Modelling for SS-304 Material.
Following is the geometry:
In property module I've created the material, specifying...