The vessel is already constructed, we are currently using a hybred device which is a Berthold Nucleonic Density measurement device connected to a Enraf servo motor. This has made for an interace profiler, we no longer require the profile option and the device needs scrapping due to mechanical...
Its pure HF Acid, the temperature range of the vessel is -15degC to 120degC and the max pressure is 18.5barg. The wall material is killed carbon steel (21mm thick. The range is 9.1m. No set accuracy, but as good as possible.
I want to measure the continous level of HF Acid in a 10m high vessel. I have to use a radioactive level measurement device as they are the only type to be completley non-contact. Can anyone recommend a Radioactive level device?
So far I have only came across the models from Ohmart-Vega, E+H...
I am currently looking at installing an Endress + Hauser Micropilot M FMR231 Level radar on a 13m HF column. Unfortunately the only nozzle available to connect the radar to is directly in the centre of the vessel, this is not ideal for radars as the walls give off false echoes that reduce the...
Are there not any serious safety implications on using the Fisher device with it being in contact with the process? Is there a risk involved when calibrating it also?
Our current device is a Berthold radioactive density measurement device that like yours send the source and detector up and down...
I want to measure the interface levels in a Hydrofluoric acid settler. Due to the nature of HFA a non-contact measurement device is strongly preffered. So far the only non-contact solution that appears to be capable of measuring the various interface levels is a Vega nucleonic density...
I want to measure the interface levels in a Hydrofluoric acid settler. Due to the nature of HFA a non-contact measurement device is strongly preffered. So far the only non-contact solution that appears to be capable of measuring the various interface levels is a Vega nucleonic density...