  1. scbiomed

    Video images from C-Arm

    I have an application where a podatrist would like to download images from a C-Arm to his computer. The C-Arm has a 1volt p-to-.p b/w video output. Is there an inexpensive way to accomplish this without changing the ii camera to a digital one?
  2. scbiomed

    Drive gear coming loose on motor shaft

    Recently I've been called to repair several chiropractic massage tables. They all have the same problem. The chain drive gear becomes loose on the motor shaft and slides foward. There are two set screws and the shaft is keyed but it does not have any flat spots. Tightening the set screws is...
  3. scbiomed

    Service Rates

    As an independent service provider (self employed medical equipment repairman) I am regularly questioned about the hourly rates I charge. Sometimes I am asked why my rates are so high but I am equally asked how my rates can be so low. This has caused me to question if I am charging properly...
  4. scbiomed

    ECG cable electrode clips.

    When checking out ECG cables don't overlook the plastic clips which attach the patient leads to the electrodes. Damage is easy to see on the stress type clip which snaps onto the top of the stress electrode It is usually just mechanical. Problems with the resting type clips which attach to...
  5. scbiomed

    Active medical equipment repairers

    This is a reply to inquiries made by Walter Harris. I hope your questions were asked in the spirit of professional curiosity and not an attempt to discredit me or Abendrinal. I have been in the medical equipment maintainance field for over twenty years. I have a degree in electrical...
  6. scbiomed

    Sharplan Epilight Hair Removal Laser

    I have two Epilight units which shutdown. I get a missing voltage, short message. Does anyone have schematics or information on these systems?
  7. scbiomed

    How to identify ECG cable failures.

    Patient cable failure is probably the most common cause of unacceptable ECG tracings. Patient cable failure can show up as artifacts, noisy tracings, failure to acquire signal or a long time to acquire a usable signal. On many of the older cables and most stress test cables individual patient...
  8. scbiomed

    Intermittant output of Burdick ECGs.

    Over the past several years I've come across many Burdick ECGs where the operator complained of only flat line tracings or units unable to acquire input sgnals. When I hooked a simulator up and ran an ECG it would usually come out ok. Sometimes after several such runs the problem would...
  9. scbiomed

    Active medical equipment repairers

    When I joined this forum I had hoped to contact other independent service providers and exchange service tips, schematics, standards and related information over the internet. Are there others out there with the same interests or am I in the wrong place?
  10. scbiomed

    Sony video printer schematic

    I am looking for a schematic for a Sony video printer power supply. Model #UP890MD
  11. scbiomed

    Schematic for Sony video printer.

    Where can I obtain a schematic for a Sony video printer model UP 890MD. I need a schematic and information on the power supply.