Thank you lightecho. I had read the post and already knew there was no butterfly vavle w/actuator listed for the service. I have a supplier trying to push an Inbal deluge type valve for tank filling and the AHJ and I have some reservations. I was looking for other suggestions
I am designing a system utilizing a 60,000 gallon above ground tank per NFPA 22 and would like to locate a supplier for a listed indicating control valve for automatic filling of the tank.
Does your company take in to account the Fundamentals Exam? For example in this state if your graduate from an ABET accredited program you are eligible for the F.E. and eventually the P.E. whether or not your degree is in Engineering or Engineering Technology.
mbensema would you still draw the...
I use to run generators on landfill gas @ 45-50% methane. It's all in the volume. The engine manufacture will tell you how many BTU's /min the engine requires. You size the supply system to feed the engine what it needs. Increase the volume in relation to the methane percentage. Use larger pipe...
Thanks for the reply, but I licked this one a couple of days after I posted. I used a shell execute command to launch the DAQ. I set the preferences of the DAQ file to begin collection of data at startup, and i used a message box to pause the execution of the code until the DAQ was running.
I am using a querytable.refresh command to refresh the data in a column. the data is being transferrred from a DAQ application and being placed into the column each time the query is refreshed. I am then picking the last value in the list and using it as a value in another table. I wrote the...
I am using Excel to analyze data generated from a linear encoder and a pressure transducer(plotting pressure verses distance).I am using a shell execute command to open the proper motion profile file(Compumotor) and data aqusition file(Dasylab). Does anyone know a way Excel can actually start...