  1. vinya

    DRIZO / Coldfinger Technology

    Can anyone throw some light on solvent circulation in Drizo? We seem to be having unending problems with solvent/ higher ends collecting in lean glycol, also can't seem to have a continuous circulation for more than few hours before the solvent lands in the lean glycol instead of the solvent...
  2. vinya

    DRIZO / Coldfinger Technology

    Dear Wartono, Drizo Technology utilises heavier fractions, especially BTEX compounds from the vent/off gases generated from the reboiler/ stripping column of the glycol regeneration plant for further purification of lean glycol. Thus instead of using fuel gas as the stripping medium in the lean...