I would contact Krohne. They have a partially filled mag meter offering and they have extensive waste water experiance. They will likely have a reference.
We have had good success with laser transmitters in platic chip and pellet silos. Typically if the laser pointer can hit the level the laser transmitter will work. There are also some special fill and keep features that can be used when filling the silo. Coating issues should be elimibated...
When refering to DN600 are you refering to valve size?
Are you meaning lined or sleeved plug valve? Lined means that the whole interior of the valve is lined with typically a Teflon material. This is typically used in corrosive services. All "wetted" parts are typically Teflon.
Sleeved...
Given the size of the line being 30" and I am assumeing an ANSI 150# or 300# tank rating or less I would suggest you look at a Triple Offset Butterfly Valve. These are typically firesafe to API 607 4th edition and are zero leakage. I would first contact Adams Valve in Houston TX or if you are in...
If 600F at 100 psi is your design temperature and pressure this application will fit soft seated materials. Xomox makes plug, ball and butterfly valves that will fit this application. SVF also makes ball valves that could work.
If 600F at 100 psi is your acual temperature and pressure I would...
I have several 3", 4" and 6" butterfly valves with double acting air to air actuators on them. The valve seat is a dovetail design. The actuators have no travel stops. When solenoid is energized to open the valve the valve disc suddenly pops out of the seat.
I have heard that a cartridge...