  1. schlebda

    Hart Communications Bridge

    Hi, Does anyone know of a HART communications bridge device that couples bi-directional HART communications between two different 4-20 mA current loops? Meaning, no DC signal coupling between the two loops, transformer isolation with bidectional gain in a single packaged device would nice...
  2. schlebda

    Two-wire 4-20mA specs / expectations below 4 mA

    Thanks for your input on this topic. Yes, apart from the valve positioners users that take advantage of the embedded positioner features to achieve full valve seating, I wanted to learn if there was a standard or accepted pratice for those people that choose 3.85mA, or 3.80mA, or 3.75mA or...
  3. schlebda

    Two-wire 4-20mA specs / expectations below 4 mA

    Is there an industry standard or performance expectation for 2 wire 4-20mA output devices (actuators, positioners) for signal levels below 4mA? For example, many field transmitters incorporate special signal indications outside the 4-20mA interval for alarm levels or diagnostic indications. And...
  4. schlebda

    Need a high-temperature CO2 and O2 analyzer

    See if this helps: http://library.abb.com/global/scot/scot212.nsf/veritydisplay/42b57838f43ec2828525711b001f507f/$File/D-NO-SMA_2.pdf
  5. schlebda

    Orifice Plate Flow

    Try any orifice flow sizing utility, there's lots of them. http://www70.de.abb.com/fpd500/gui/index.html
  6. schlebda

    Ovation Hart I/O Modules & Hart Hand Held Terminals

    Does anyone know whether any Hart hand held terminals can be used together with Ovation Hart I/O modules? I am thinking that AMS is the recommeded approach where Hart communications passes through the Ovation Hart I/O module but I do not know if loop connected Hart hand held terminals (ie...
  7. schlebda

    Dual (stacked) DP Flow Transmitters

    I am thinking that stacking DP transmitters is ok. And I have done it for gases and liquids. And I agree for the most part with the 3 points but I would like to add that you have to watchout for density variation in the flow (liquid vs gas, and P & T variations), so you might want to stack...
  8. schlebda

    Ovation Hart IO interface to Hart Instrumentation

    I am pretty well acquainted with Hart but not at all acquainted with Ovation Hart I/O, except that I know that the Hart modem is multiplexed 8:1 on the Ovation Hart I/O module. And I am not seeking a comprehensive understanding of the Ovation system. I just want to know the basics of what the...
  9. schlebda

    Ovation Hart IO interface to Hart Instrumentation

    I am looking for some basic information from users of the Ovation Hart IO interface using Hart communications for data exchange between Ovation and instruments. Are there any particular requirements on the instrument; ie, is only Hart burst mode operation supported, what Hart commands are...
  10. schlebda

    Very high turndown flow meter

    Is it a conductive liquid, like water, or is it oil? Did you look at magmeters?
  11. schlebda

    Slide Rules. Collecting and discussing.

    I still have my Pickett Model N-16-ES and manuals
  12. schlebda

    JEM 1252-1991

    I am trying to find the subject Copper 10 RTD standard, any suggestions would be appreciated. The standard is listed in the HART Communications Foundation Document HCF_SPEC-160.4, Temperature Device Family Specification, code 101 . I did not have luck calling the Hart Foundation.
  13. schlebda

    Need Small Control System Recommendation

    I seek recommendations for a small control system suppliers that can handle about 12 analog inputs, 12 analog outputs, 10 digital inputs and 10 digital outputs, with mixed analog and digital control, easily configurable control with one easily configurable operator console. Outdoor...
  14. schlebda

    Minimum Spacing 1/2"NPT Enclosure Conduit Entries

    Is there some reference (code or standard) basis for the minimum separation distance between 1/2"NPT conduit entries on enclosures for Div 2 and/or explosion proof Div 1 locations? Thansk in advance for any advice.
  15. schlebda

    JLCC x PLCC IC packages

    I don't think there is any difference. It used to be a little scary when the L stood for leadless in ceramic packages. As far as I am concerned all PLLL's have either J leads or gull wing.
  16. schlebda

    I Need Xicor X20C16J NOVRAMs

    Been there, done that. Result: no satisfaction or parts. I am working outside the box by posting my desperate message on the eng-tips site. The whole story has many trite and boring details but it is not complicated; ie, I need parts. Thanks for the reply but I still seek some good advice...
  17. schlebda

    I Need Xicor X20C16J NOVRAMs

    I need 500 Xicor X20C16J NOVRAMs for ongoing production of an existing product, and I would appreciate any good suggestions. Thanks.
  18. schlebda

    New Part Number Request forms

    Start by gathering data on your existing parts, include costs; then prepare a database of parts. Better engineers tend to look through existing parts provided it is not cumbersome to do so, lazy engineers don't bother to look.
  19. schlebda

    4-20mA to HART Converter

    Unfortunately for me, I have been looking amongst the most obvious suppliers of HART equipment, including the two suppliers already mentioned but while there are several manufacturers of HART to 4-20mA (aka Tri-Loop contraptions) the best that I have been able to identify for the reverse, ie...
  20. schlebda

    Baily Polyjet

    Try new spelling for Baily; ie, Bailey http://www.rexa.com/industries/water_waste/water_htm/ww-1.htm