Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: nitro
  • Order by date
  1. nitro

    Calculating Kw

    Thanks Blacksmith & Informanic, now if I can just convince the old-timers here. You would think this would be simple.
  2. nitro

    Calculating Kw

    Thank Infomanic, but we still have some old-timers here think there's a difference depending on hertz, I'm not one of them. Ant published works on this? Thanks again. Nitro
  3. nitro

    Calculating Kw

    I'm an electrical engineer in the US and need to clarify a dispute with a co-worker. We are working on a project in Russia where voltage and hertz are different from the US. We are sizing Generator Sets and have to calculate kVA to kW @ 50Hz. What is the formula for converting kVA to kW for...
  4. nitro

    Gas Fired Generator

    Olympian makes gas generators starting at 9kW. You will need to contact your local Caterpillar Dealer for the Olympian line.
  5. nitro

    AVR - 3 Phase Sensing

    ccdubs, I have to input my thoughts on this subject. Caterpillar has led the industry in regulators with three-phase voltage sensing. Most Caterpillar generators are equipped to sense three-phase voltage. Three-phase sensing averages all three-voltage phases, resulting in better regulation...
  6. nitro

    CT Saturation

    Chuncky hope this helps. CT Saturation DC Saturation When a fault occurs the current usually contains a DC component. The total flux required to produce the offset drives the CT into saturation. Flux reaches saturation during the positive cycle and the exciting reactance decreases shunting...
  7. nitro

    3 phase curreent calculation

    mpparent, you equation only holds true if you have a unity (1.0)power factor. To accurately determine 3 phase ac you must factor in you pf. I=P/(sq.rt(3)*V*pf)
  8. nitro

    Generator Neutral

    Grounding 1. In any generator set installation, the frame of the generator must be positively connected to an earth ground or to the hull of a vessel. This connection is the first one made at installation, and the last one to be removed. If the generator set is on flexible or resilient pads, the...
  9. nitro

    STARTING OF DIESEL ENGINE THRO' CONTROL PANEL

    An Automatic Transfer Switch is the least expensive way to go. I assume this is one (1) Standby Generator application. You would need to add acessories such as battery charger and jacket water heaters to ensure 10 second starting. I design these systems for a power systems company and if you...
  10. nitro

    CT calculation

    Joan 271273 please forward me the CT info you have it would be greatly appricated.
  11. nitro

    nitrogen pipe sizing

    need a calculation for sizing nitrogen piping with these parameters. 250 psig working pressure 11 cfm volume -65 F temperature 418 ft. of run also need info on pressure relief valves.

Part and Inventory Search

Back