Search results for query: *

  1. PeteBennett

    ANSI Flange Question

    Gents, my appreciations, Its a useful website StoneCold
  2. PeteBennett

    ANSI Flange Question

    Dear All, Am sure this is a simple question, but I do not work with ANSI equipment very often, I have a specification that is written Class300 B16.5RF 250 - 500 AARH. Can someone please tell me what the AARH stands for? Thanks
  3. PeteBennett

    pump design

    Sorry guys, getting old, but do you want mechanical or electrical?
  4. PeteBennett

    Boiler Blowdown Vessel Design

    Are you designing in Europe, or the USA? If its Europe then there will be PED issues, I have just done it for my company here in the UK
  5. PeteBennett

    sizing of steam drain lines

    Send me an e-mail address, and I'll send you the sizing charts we use here at Spirax Sarco, with a trap sizing booklet etc
  6. PeteBennett

    Stainless Steel Corrosion

    I have a client who is having corrosion problems on a stainless steel heat exchanger skid. At the start the brazed heat exchangers (s/s plates) were literally being eaten away (secondary side). I thought this could be a production fault so replaced the unit with another one. This lasted a...
  7. PeteBennett

    Y Strainers

    Agreed, would advise a 100mesh on start up. Also some of our clients use a ball valve srewed in to the base plate of the strainer , to blow it down, during start ups. From experience on the larger strainers it is a goods idea as it stops it blocking and thus keeping it efficient. And it means...
  8. PeteBennett

    Ideas sought for arresting the fall of a large mass

    Could always follow the Pyramid Builders lead, and use sand jacks in support. Cheap and cheerful, no moving parts, all you have to do is work out the flow orifice size.
  9. PeteBennett

    Main Steam Line Condensate

    Sorry quark, no more descritive as I do work for Spirax Sarco but thought it a bit off to metion it (sounds like a sales pitch otherwise) A question for you though as you have been on this site longer than me, and Robin sorry for ambushing your string, is there a specifc group for steam issues?
  10. PeteBennett

    Main Steam Line Condensate

    Agreed, dumping from main line at 10 Barg into 1.5 Barg could cause the condensate line to back pressure on traps further down line, even with non return valves, they may not be able to over come it. With 10Barg, which is about 100m of motive pressure do you not have any atmospheric vessel near...
  11. PeteBennett

    boiler water wall tube leakage

    Would also check if you are returning condensate back to the feed tank, do an analysis on this? Are you blowing your boiler down often enough i.e Bottom, Side and TDS? Is your feed water being oxygenated from some source? If you have a water preheat system from say, excess flash, whatever, is...