Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. supersurf

    V5 Surface Healing and Join

    The maximum Join merging tolerance you can specify is 0.1mm. As in previous responses, Join will not modify the underlying surface. i.e if you have a step od 0.1mm and run a NC tool path over the join, you would still see a step in the result, yet visually you woul not see any step in the CAD...
Back
Top