Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Tonka73

    Pipe work and frames within Atex areas

    Hi all I need some help with pipework and frames within Atex areas. These are both chemical dosing units with pumps and pipework mounted on frames/ enclosures 1) can Plastics be used within a zone 2 environment, I assume there is an issue due to static??? 2)If for example the pipework was...
  2. Tonka73

    Potentiostatic method for Clorine

    Hi mate There are a few manufacturerers that produce residual analysers. If you are looking for products Prominent do a cheap alternative to the W & T Deplox. But you need to check the pH prior to purchase as there is a point where the pH correction probes will not accurately correct the...
  3. Tonka73

    Selection of Chlorinator system for deep well water supply

    Rich Real big subject mate in my opion hypo dosing would suit you best. Points to remember are hypo will "gas off" so keep it as cool as possible (around 15 degrees C is good). Also self bleeding dosing pumps (see Prominent pumps) these work really well. But there are loads of alternatives...
  4. Tonka73

    High Pressure Sodium Hyperchlorite injection

    Misco 41 Hypo will eat the stainless steel (any grade) injection lance/ Quill But Hastelloy C as I remember is good for chlorine gas and Sodium Hypochlorite. Hope this helps
Back