  1. schola

    Nois level inside Anechoic Chamber

    Dear sirs: If an anechoic chamber was for sound isolation, inside noise level should be below 20 decibels. Is the same requirement mandatory or advisable for RF anechoic chambers? What is the noise level usually recommended? Thanks schola
  2. schola

    Radio-frequency Anechoic Chamber Noise Level

    Dear sirs Acoustic anechoic chambers require noise levels as low as 20- 10 db. These noise levels have to be applied to Radio-frequency anechoic chambers also? Tanks and regards schola
  3. schola

    Broadcasting Digital Transmisor Heat Dissipation

    A 100 KW AM signal digital. Regards, schola
  4. schola

    Broadcasting Digital Transmisor Heat Dissipation

    Dear sirs: I am Mechanical Engineer working in Air Conditioning project. In order to conclude a preliminar cooling looad estimation, for a room containing a 100 KVA digital broadcasting transmissor, I need estimate how much heat that kind of equipment realease to the surrounding space. Could...
  5. schola

    SHORT WAVE BROADCASTING TRANSMITTER HEAT REJECTION

    Dear friends: I´m estimating cooling load for 100 KW broadcast transmitter room. Do you have any index I could use for estimate heat rejection from the transmitter? Thanks, schola
  6. schola

    AIR DIFFUSION PERFORMANCE INDEX (ADPI)

    Dear friends: SMACNA and terminal devices manufacturers literature I have consulted advise TL50/L and max. ADPI for Circular Ceiling Difussers. Do you have such an information for Rectangular Ceiling Diffussers?. Thanks in advance, schola
  7. schola

    PRIMARY - SECONDARY CHILLED WATER DELTA TEMPERATURE

    Dear sirs: Different Desing Dlta T are frecuently or advisable, as this case i have found: Primary Delta T. 12.00 ºF, Secondary circuit: 10.00 ºF. ? Regards, schola
  8. schola

    CHILLED WATER NOISE

    Dear sirs: Do you know Noise levels and/or dbA of typical Horizontal Centrifugal Frame Mounted Chilled Water Pump. HP = 7.50 - 10.00 HP? Thanks in advance. schola
  9. schola

    HOSE VALVES AND PUMP TESTING

    Dear sirs, In accordance to NFPA-20, hose valves shall be installed for pump testing. What could be the advisable time the pump test should last? Regards, schola
  10. schola

    AM/FM BROADCASTING STUDIOS

    Radio Studio. Regards, schola
  11. schola

    AM/FM BROADCASTING STUDIOS

    Dear sirs: Do you know a good literature gealing with HVAC desgign for Broadcasting Studios?. Thaks in advance, schola
  12. schola

    FIRE & SMOKE DAMPER

    Visit Greenheck Website. Regards, Schola
  13. schola

    CHILLED WATER 6" DIAMETER RISER SUPPORT

    Dear friends: Do you know where can I get information and detail about riser support decribed before? The riser runs inside vertical masonry chase. Thanks in advance, schola
  14. schola

    ASTM A-120 GALVANIZED CHILLED WATER PIPE

    Dear sirs: I use to specify ASTM A53 Gr. A or B for chilled water pipes 3" diameter or mayor. What kind of problems could be arise is ASTM A-120 theraded pipe is used in lieu of A-53 carbon steel, diameters 3" to 6"? 8"? Thanks, schola
  15. schola

    HORIZONTAL CHILLED WATER COPPER SPAN

    Dear sirs: Do you know any standard or basic practice in order to specify spans for insulated cw copper pipe support?. I am using Type L, diameters 1/2 to 2.1/2 inches. Thanks, schola
  16. schola

    Chilled Water Precision Air Handling Unit

    Dear sirs: I've been estimating chilled water cooling coil "delta P", finding very diffferent values among common manufacturers ( DataAire (45 ft H2O), Liebert (10 ft), , APC(20 ft). for the similar equipment Do you have a rough or practical standard value? Regards, schola
  17. schola

    CHILLED WATER COPPER PIPE FITTINGS

    Dear sirs, I am specifiacting M Hard Copper Tubing for chilled water system. My question deals with choicing of fittings. What do you think is the most advaisable: Cast brass? wrought copper? wrought brass? Soldered, threaded? Working pressure will be 90#. Thanks in advance. schola
  18. schola

    firefighting piping

    Yes. Regards, schola
  19. schola

    pipes on the dike wall

    Those pipes will vibrate?. Regards, schola
  20. schola

    Plenum box

    Trane has issued the brochure "Fans", dealing with this question. Consult Trane web page. Regards, schola