  1. brazilianjj

    Sizing a Pressure (Bladder) Tank Question

    I will be needing a booster pump station with a supply tank and a pressure tank to supply potable water for an emergency shower. Unfortunately, I have to provide this system because there is not a reliable source of potable water. I’ve sized the booster pump station to deliver 20 gpm against...
  2. brazilianjj

    Need advise on Capping the ends of Asbestos Cement Pipe?

    I have a 8 inch diameter fire water pipe buried in the ground at our plant. The pipe is ACP asbestor cement pipe. We're creating a bypass of the line where will need to cut and end cap the pipe in two locations. Someone had suggested that the pipe could be capped with a mechanical joint end...
  3. brazilianjj

    ASTM A312 Testing Requirements??

    Is there someone that would help me out with the requirements of ASTM A312? I specified a stainless steel pipe 316L that shall conform to ASTM A312. My pipe will range in size from 2" to 10" in diameter. With referencing ASTM A312, what are the quality control tests the manufacturer...
  4. brazilianjj

    Backing Rings for Fiberglass Pipe Flanges?

    At one time, backing rings were recommended for frp pipe flanges. Large frp manufacturers such as Ameron and Fibercast have told me that backing rings are not necessary because of the better quality in flange production. Can provide me with the reason why they are not used anymore? Also, I'm...
  5. brazilianjj

    Looking for 6" Pressure Reducing Valve (plastic or stainless)

    I would need a control valve. I found one manufacturer for stainless steel. The company name is Cla-Val. But, haven't found anything in pvc.
  6. brazilianjj

    Looking for 6" Pressure Reducing Valve (plastic or stainless)

    Does anybody know of manufacturer(s) that carries a 6" pressure reducing valve in pvc and stainless steel 316? It seems as if most pvc companies only carry the valve up to 4".
  7. brazilianjj

    Perforated plate pressure drop calculations?

    using that formula, the ratio of passage area to total area is 7.66/379.94 = 0.02. So the holes cover about 2% of the total area... it doesn't seem like much of an opening.. I'll have to double check.,
  8. brazilianjj

    Perforated plate pressure drop calculations?

    I'm trying to figure out how to calculate the pressure drop of a perforated plate! Could you provide me with assistance or information? My current project is the design of a biotrickling scrubber. It is essentially a biological scrubber using lava rock with nutrient rich solution to degrade...
  9. brazilianjj

    Perforated plate pressure drop calculations?

    I'm trying to figure out how to calculate the pressure drop of a perforated plate! Could you provide me with assistance or information? My current project is the design of a biotrickling scrubber. It is essentially a biological scrubber using lava rock with nutrient rich solution to degrade...
  10. brazilianjj

    looking for air velocity criteria for frp duct/pipe used 4 foul air?

    I'm currently working on the design of odor control facilities for a wastewater treatment plant. We plan to use FRP pipe for convey foul air to odor control scrubbers. I've seen guidelines that limit the air velocities in pipes/duct to less than 2500 fpm or 3000 fpm to reduce the problem of...
  11. brazilianjj

    LOOKING FOR DESIGN CRITERIA FOR AIR VELOCITIES IN DUCTS

    I'm currently working on the design of odor control facilities for a wastewater treatment plant. We plan to use FRP pipe for convey foul air to odor control scrubbers. I've seen guidelines that limit the air velocities in pipes/duct to less than 2500 fpm or 3000 fpm to reduce the problem of...
  12. brazilianjj

    Vcone Flowmeters - Looking for manufacturers

    Does anyone know of any other manufacture other than McCrometer that manufactures VCone flowmeters?