Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. minorchord2000

    ASCE 7-16 Section 12.14.3.2 The use of the overstrength factor

    Subsection 12.14.3.2.1, equation 12.14-9 specifies that Emh = 2.5*Qe. My question is when to use the 2.5 factor and when not to. The Code is unclear. I am designing anchorage forces for a vertical rigid steel storage tank and I use equation 15.4-5 to calculate the lateral seismic force, V...
  2. minorchord2000

    welded steel pipeline above ground thrust issues?

    I am a structural engineer and I have a question: I have a 24" diameter steel pipeline under about 40 feet of hydraulic head with occasional changes in direction of 45 degrees each. The pipes are welded together using groove welds. Do I need to account for thrust forces at the bends even...
  3. minorchord2000

    Full height concrete abutment walls subjected to scour

    We have been tasked to design full height concrete abutments on spread footings subjected to scour. The bridge structure will be an ACROW steel bridge similar to a Bailey bridge. The single span is 110 feet from CL bearing to CL bearing with HL-93 loading. My question concerns scour from...
  4. minorchord2000

    Pedestrian Bridge Horizontal Wind Load Application

    Thanks for your great post STrctPono. These trusses are only 3'-4" apart and they are HSS 4x4s. Since they are relatively close, I will use your recommendation for wind on the leeward truss.
  5. minorchord2000

    Pedestrian Bridge Horizontal Wind Load Application

    For a pedestrian bridge does the wind force calculated get applied to BOTH trusses or only the windward truss?
  6. minorchord2000

    Concrete Drilled Shaft Tip Elevations

    After determining the depth to fixity for concrete drilled shafts based on ADOT (Arizona DOT) Geotechnical Design Policy DS-3, how does one determine the tip elevation beyond the fixity depth? Is there a good rule of thumb (assuming that even exists) based on the shaft diameter?
  7. minorchord2000

    Drilled Shaft Tip depth beyond fixity depth

    After determining the depth to fixity for a concrete drilled shaft, what is the rule of thumb (if such a thing exists) for the increase in depth beyond fixity to the tip elevation?
  8. minorchord2000

    Help me come up with a name

    RWW0002 I could amend OME Engineering to OLD MAN EMERITUS ENGINEERING.
  9. minorchord2000

    Cross Hole Sonic Log Testing of Drilled Shafts

    All shafts...of all the bridges I have designed here in Tucson, each and every shaft has cross sonic logging and gamma-gamma required testing. However, in the local design community there is continued heated discussion about where the testing tubes (PVC) are to be located. I prefer that they...
  10. minorchord2000

    Help me come up with a name

    Since I am older in my 70s, my name would be OME Engineering, LLC. "Old Man Engineering".
  11. minorchord2000

    Two-Way Slab definition

    There are some nice tables with different aspect ratios in "Design of Concrete Structures" 12th Edition by Arthur Nilson, pages 408-411. The tables give you coefficents to calculate the moments in either direction.
  12. minorchord2000

    API 650 Tank Question

    Thanks so much for that clarification.
  13. minorchord2000

    API 650 Tank Question

    I am tasked with designing a tank to hold acid (sg = 1.84) and one of the design criteria I have from the owner says: "Tank will be rated for 6" water pressure and -.4 oz vacuum." Can anyone shed some light on what this means? I am a structural engineer, not a mechanical engineer. The tank...
  14. minorchord2000

    Reinforcing Tall Residential Concrete Basement Walls

    I always design the walls using standard methods in accordance with ACI 318. First I design the walls assuming a cantilevered condition with the outside soil causing tension on the outside face. I design the footing assuming a cantilevered condition but sliding may be resisted by the basement...
  15. minorchord2000

    Bridge Demolition Cost

    Hello: We have a bridge here in Tucson that might be scheduled for demolition due to its age and inadequate inventory and operating ratings. The bridge is a 6 span, non composite structure: total length = 363 feet: out to out width = 64 feet. Superstructure is composed of 4 feet wide...
  16. minorchord2000

    HS20 Wheel Load directly atop a concrete wall

    Thanks HotRod 10 My trench is only 12 feet long so the most I can get on the trench is 3 wheel loads. As the wheel load is distributed downward, are the pressures additive at the bottom once the pressure triangles intersect? Is it appropriate to use the 1.33 dynamic load allowance for the...
  17. minorchord2000

    HS20 Wheel Load directly atop a concrete wall

    I am designing a narrow concrete trench with proprietary traffic rated grating which spans between the walls. The wall height of the trench is in the order of 5 feet and the wall thickness is tentatively 6 inches. When the wheel load of 16 kips + impact is directly over the wall, how does this...
  18. minorchord2000

    Renovating Box Beam Non Composite Deck to Composite Deck

    Yes HotRod: I thought of that. This old bridge uses 250 ksi tendons f'c = 5 ksi for the girders and grade 40 for the mild steel. I will use the oldest AASHTO we have. Thanks again for your timely and thoughtful responses. The existing stirrup layout could be the deal breaker in trying to...
  19. minorchord2000

    Renovating Box Beam Non Composite Deck to Composite Deck

    HotRod10 and wiktor: Thanks so much for your responses. The prestressing tendons are straight and are all within the bottom flange of the girder. There are 26 straight 3/8" diameter strands (0.08 in^2/strand). The shear reinforcing is located within the centerlines of the vertical stems of...
  20. minorchord2000

    Renovating Box Beam Non Composite Deck to Composite Deck

    Gentlemen: I am analyzing an old 3 span non-continuous, pre-cast box girder bridge, with simple spans of 49.25 feet each. The superstructure is 27 feet wide and consists of 9 voided box sections 3 feet wide and 27" deep. Currently the driving surface is only about 2" of asphalt. Our scope of...

Part and Inventory Search