  1. EricCabrol

    Material from xy data

    I'm not sure I understand your question properly, but here's an example assuming metal plasticity : *MATERIAL *PLASTIC stress_1,strain_1 stress_2,strain_2 ... where the pairs (stress_i,strain_i) define the material's curve.
  2. EricCabrol

    hit specific time values with automatic time step incrementation

    As corus said, why don't you split your step ? Another solution would be to modify the default Dm factor under the *CONTROLS,PARAMETERS=TIME INCREMENTATION card (see Keywords Ref Manual) : - specify an adequate initial increment - set Dm to 1.0 But it is imho far more complicated ... Eric