  1. VishalSathe

    Design of low pressure flanges

    Manway is near top of vessel, so 2m height for hydrotest was not achieved. No design calculations are available for the manway flange.
  2. VishalSathe

    Design of low pressure flanges

    @LittleInch Vessel is holding only gas. It was hydrotested full of water.
  3. VishalSathe

    Design of low pressure flanges

    Hello everyone, thanks for your quick responses. really appreciate that. I am attaching the snapshot of the nozzle details for your refernece. Few comments: 1) The vessel is indeed neither ASME U stamped nor PED compliant, as original design pressure was 6kPa. Hence the design is based on...
  4. VishalSathe

    Design of low pressure flanges

    Hello, I am currently working on a case for re-rating of pressure vessel. The vessel is currently designed for 6 kPa and needs to be re-rated for 20 kPa. I am checking the manway flange design (its a non standard flange- ring type flange with plate used as blind cover). I tried ASME Appendix 2...