Search results for query: *

  1. ThePenguin

    Flexible Diaphragms in RISA-3D Without RISA-Floor?

    Josh, thank you. The semi-flexible diaphragm modeled with plate elements seems to work just fine when the "plane stress" option is used. I did not get too deep into it but the semi-flexible VS flexible issue seems inconsequential when the plate parameters represent diaphragm materials that would...
  2. ThePenguin

    Flexible Diaphragms in RISA-3D Without RISA-Floor?

    So if I just get RISA-Floor, will life be good in terms of flexible diaphragms?
  3. ThePenguin

    Flexible Diaphragms in RISA-3D Without RISA-Floor?

    Actually I think the issue is with me, I'm still in a hand calculation mind set... Is there really any need for a "flexible diaphragm" if one is using software? Couldn't the diaphragm just be modeled with a plate using an appropriate in plane stiffness to account for nail slip etc? In which case...
  4. ThePenguin

    Flexible Diaphragms in RISA-3D Without RISA-Floor?

    Is there any way to model (efficiently) a flexible diaphragm in RISA-3D without using RISA-Floor? I have finally forsaken portal method and moment distribution spreadsheets and purchased a copy of RISA-3D to join the 21st Century, only to realize that I might need additional software to do...
  5. ThePenguin

    how to identify shear studs in existing building?

    hs2112, I'm in the US Northeast, and the last time I had a GPR done inside a building it was something like $1,200 for the day. There was a general contractor in the middle of it, and it was a government job so I'm not sure how the markups compare to your situation. The purpose of the GPR...
  6. ThePenguin

    how to identify shear studs in existing building?

    Did you say that you had the drawings? If so I would imagine that the shear studs would be called out on the drawings? If no drawings are available you can look to the existing structure for clues. If some of the member sizes are too small for the original loads when analyzed as non-composite it...
  7. ThePenguin

    New Steel Beam to Existing Concrete Column connection Design

    The only thing holding up the beams is the clamping pressure? I have seen a similar connection where the rods were drilled right through the column, in which case you would conceivably have to shear the rods to drop the beam. I have also seen the same thing done with wedge anchors in blind...
  8. ThePenguin

    Thicken slab for cmu wall

    To connect the dots... Table 3-2 of the aforementioned DOD manual gives an allowable wall load of 565PLF for a 5" slab (wall on interior of slab). Taking the weight of an 8" CMU wall grouted 48" OC as 47PSF (ASCE-7 Table C3-1) this would give 470PLF for a 10' wall. This would agree with the...
  9. ThePenguin

    Thicken slab for cmu wall

    This topic is covered in DOD UFC 3-320-06A "Concrete Floor Slabs on Grade Subjected to Heavy Loads." This is essentially a reprint of US Army Technical Manual 5-809-12. Either way it can be obtained for free at the following link: http://www.wbdg.org/ccb/DOD/UFC/ufc_3_320_06a.pdf I believe...
  10. ThePenguin

    How to calculate point load on suspended slab

    I believe that the equation to which Jike refers can be found in "Computation of Stresses in Bridge Slabs Due to Wheel Loads." by Westergaard, published in Public Roads Vol 11 No. 1 1930. In this paper Westergaard provides an analytical elastic analysis of concentrated loads on a slab, and gives...
  11. ThePenguin

    NEMA ST-20

    The NEMA website lists ST-20 "Dry Type Transformers for General Applications" as Rescinded. Does anyone have any idea what standard will fill the void? http://www.nema.org/stds/st20.cfm
  12. ThePenguin

    Weight of Oil Storage Tank

    From the outter dimensions less the thickness of the foam you should be able to find the area of the steel. However you will need the thickness of the various parts of the tank to get the volume and thus the weight of the steel as EdR proposed. If the tank is UL listed (UL-142 etc) the UL...
  13. ThePenguin

    textbook for 2005 AISC Spec

    If you are interested in the direct analysis method, you can view a quick "Boxed Lunch" seminar on the subject for free on the AISC website at this link http://www.aisc.org/Content/NavigationMenu/Learning_Opportunities/eLearning/Course_Details/A_New_Approach_to_Design_got_Stability.htm Second...
  14. ThePenguin

    Reinforced Concrete Slab Repair

    I would recomend checking "Structural Renovations of Buildings" by Newman for some ideas. I believe he may have presented a solution for a similar slab issue. I will check my copy when I get to work tomorrow.
  15. ThePenguin

    Slab of Grade Reinforcement Coverage

    In addition to my above post, a "fact sheet" on the WRI website says the following: "In the case of the lower layer, when the concrete slab is placed on a well-constructed base course (normally graded, compacted and porous), many who design floors consider 1.5” of clear cover below the steel...
  16. ThePenguin

    Slab of Grade Reinforcement Coverage

    I believe the document Teguci is referring to is ACI 360 "Design of Slabs on Ground." The only guidance given for placement of reinforcing within the slab is as follows: For Crack-Width Control - At or above mid-depth, typically 1.5" to 2" cover below the top surface of the slab. For Moment...
  17. ThePenguin

    Different Types of Water Reducers

    ASTM C494 "Standard Specification for Chemical Admixtures for Concrete" gives the following definitions: Water-Reducing Admixture - An admixture that reduces the quantity of mixing water required to produce concrete of a given consistency. Water-Reducing Admixture, High Range — An admixture...
  18. ThePenguin

    Eng. practice of allowing 5% overstress

    I would just like to point out that the AASHTO LRFD Bridge Design Specifications 4th Edition has 5% adjustments built explicitly into the code. These "load modifiers" effectively allow an additional 5% capacity for structures with exceptional ductility, highly redundant load paths, or structures...
  19. ThePenguin

    The Defination Of Laterally Support fot W-Shapes

    StructuralEIT - I agree that bracing in general need not be located near the compression flange to prevent beam instability. The AISC code refers to beam stability bracing as "Lateral Bracing" and "Torsional Bracing" with different stiffness and strength equations for each type. The...
  20. ThePenguin

    The Defination Of Laterally Support fot W-Shapes

    I would recommend you refer to Appendix 6 of the latest AISC Specification (AISC 360-05). Appendix 6 deals with stability bracing for columns and beams. With regards to lateral bracing for beams it states "Bracing shall be attached near the compression flange...". Additionally the commentary to...