Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. caneng2002

    Below Ground Plastic Valves on Gas Lines

    Thanks PEDARRIN2 - perfect just what I was looking for.
  2. caneng2002

    Below Ground Plastic Valves on Gas Lines

    I design medium pressure (5-85 psi) distribution gas lines at industrial facilities, following CSA Z662 and B149.1. The scope is usually from pressure reducing station to 10-15 feet from the buidling of the end user (upstream of PRV). Typically the sizing is below 10" and I used MDPE or HPDE...
  3. caneng2002

    Laterite Road Building - Definition Question

    Looking for some help on definition terminology. In a document on laterite roads the following data is presented Base properties PI = 15, P425 = 48; PM = 720 CBRs @ 98% BS Heavy = 24% Cum. Traffic to end 2003 = 0.28 MESA My question - 1) P425 represent a fraction but on what scale. is this...
  4. caneng2002

    Exam Problem on Dry Density and Borrow Pit

    I'm assuming in-place volumes with no account for bulking.
  5. caneng2002

    Exam Problem on Dry Density and Borrow Pit

    I'm studying for my PE exam in Geotechnical Materials and Analysis and have come across a problem that I seem to be able to do the first part but a bit confused on the second. The abridged question is this Need to fill a volume of 2100 m3 using material to be taken from one of two borrow pits...
  6. caneng2002

    Hydrostatic Test Reference for PVC Required

    Bimr Thanks for the reference - excellent. FYI this is mine site in northern Saskatchwan - I said potable but actualy for a process use routed inside a building. Thanks to everyone. Closing out this thread.
  7. caneng2002

    Hydrostatic Test Reference for PVC Required

    I have a design for a potable water system using pvc sched 40 solvent welded pipe. ASME B31.3 page 104 A345.4.2 reference test pressure of 1.5 times design pressure. Design pressure is about 100 psi based on the pump supply curve. The downstream distribution system has pressure reducers as...
  8. caneng2002

    Understanding Water Treatment Fundamentals

    I've been in civil engineering for 20+ years and during that time have danced around water/wastewater treatment and general infrastructure. I'm both impressed and jealous of the water treatment knowledge some of the posters on this website. Having recently started to gravitate to more water...
  9. caneng2002

    Alkalinity Use Question

    Greetings Based on the following equation taken from Water Treatment - Principles and Design (2nd Edition) 4Fe(HCO3)2 + O2 + H2O >>> 4Fe(OH)3 + 8CO2 I'm trying to figure out how Alkalinity used (mg/ mg Fe) of 1.8 was calculated. I can see how oxidant needed of 0.14 mg/mg Fe was calculated...
  10. caneng2002

    Alkalinity used in Fe Reaction

    Greetings Based on the following equation taken from Water Treatment - Principles and Design (2nd Edition) 4Fe(HCO3)2 + O2 + H2O >>> 4Fe(OH)3 + 8CO2 I'm trying to figure out how Alkalinity used (mg/ mg Fe) of 1.8 was calculated. I can see how oxidant needed of 0.14 mg/mg Fe was calculated...
  11. caneng2002

    oxygen concentration brine versus fresh water

    dcasto interesting. I decided to do the same thing with my performance spec, leave the O2 rates the same as water at the design temperature. Who manufactured your system. I'm having problems finding bidders for this type of de-aerator. Most vendors want to use a thermal de-aerator which has...
  12. caneng2002

    oxygen concentration brine versus fresh water

    Gents I think I upload my brine doc correctly. http://files.engineering.com/getfile.aspx?folder=61f06376-0f36-4603-bfd7-53df01e98b40&file=Sol_O2_in_Dead_Sea_Brine.pdfhttp://files.engineering.com/getfile.aspx?folder=61f06376-0f36-4603-bfd7-53df01e98b40&file=Sol_O2_in_Dead_Sea_Brine.pdf
  13. caneng2002

    oxygen concentration brine versus fresh water

    zdas I have a pdf document by Nishri and Yaakov on Dead sea brine. where do you want me to send it?
  14. caneng2002

    oxygen concentration brine versus fresh water

    Gents, thank you for your comments. gerhardl (Mechanical) At this stage I was looking for some theoretical values. zdas04 (Mechanical) my brine source is from a solution mining stream for KCl and NaCl. I'm looking at de-oxyenating it using a vacuum deaerator driven by steam (rather then...
  15. caneng2002

    oxygen concentration brine versus fresh water

    Are the O2 levels in brine lower then those in fresh water at a given temperature simply because the increased TDS of the brine prevents more oxygen from binding to other molecules? Kevin
  16. caneng2002

    Help with Motor Decibel Ratings

    I'm looking for decibel ratings for NEMA motors to compare a 600 kw tefc to WP1 enclosure. If NEMA has a maximum rating for all motors that would be fine as well. For those needing more information on why I'm asking. Its for a pumping station design where I think 600kw tefc will be too...
  17. caneng2002

    API Oil Separator with Nitrogen Blanket

    thanks mbeychok I'll try that
  18. caneng2002

    API Oil Separator with Nitrogen Blanket

    I have two produced water streams (2500 and 8500 gpm) containing oil which has been previously de-aerated to remove oxygen. The water is reused in the process after passing through the oil separator and to avoid having to de-aerate the streams again I was looking for a manufacturer of API oil...
Back