  1. farid2176

    Sprinkler in Utildor

    Do we require sprinkler in utilidor our utilidor constructed with concrete and considered as non combustable construction. and as per NFPA 13 section 8.15.1.2.2 the concealed sapce with limited access and not permitting occupancy is expemted from sprinkler please advice
  2. farid2176

    Fire hose Cabinet requiremnet

    the builidng code is Manitoba building code and NFPA
  3. farid2176

    Fire hose Cabinet requiremnet

    My project is in Churchill Manitoba 26000 sq-ft builindg 75% builing light hazard 25% ordinary hazard on site pire protection water storage tank entire builidng is sprinklerd i am wondring if we fire hose cabinet and out side hose allownce i consider my building as light hazard since the...
  4. farid2176

    Fire Pump Size and external hose stream allownce

    In my building i have 25% of the area odinary hazard 2 and rest of the building light hazard can sombody explain how external hose stream works my understanding is tha the fire truck will hook up to fire hydrant and use their hose using the fire truck pumper is that right
  5. farid2176

    Fire Pump Size and external hose stream allownce

    The project i am working on has fire protection storage tank and wall hydrant from tank directly. the firepump will provide water to sprinkler system and fire hose cabinet inside the builidng. i am not sure that if i need to add external hose alownce flow to my pump size. can sombody explain how...
  6. farid2176

    Fire Hose Cabinet requiremnet

    this is a buidling that have class rooms and residence in Toronta conservation area. school kids go there and stay for couple of days study about nature the existing builing is about 11065 sq-ft and addition is 2765 sq-ft the loacl code is Ontario builidng code and also NFPA codes applied.
  7. farid2176

    Fire Hose Cabinet requiremnet

    I am working on renovation project, the existing building does not have sprinkler system but fire hose cabinet is provide. we are adding on 3000 sq-ft to this building now the question is that if fire hose will be required for new addition or not can some body identify the NFPA section take...
  8. farid2176

    Pallet Bolier in bigger capacities

    I am looking for Pallet Boiler not the steam boiler Thanks
  9. farid2176

    Pallet Bolier in bigger capacities

    I am working on a project in Churchill Manitoba My builidng heating load is about 600,000 btu/hr and we wants to specify Pallet boiler the biggest boiler i could find is 100,000 btu/hr residential application is any body had a chance using pallet boilers bigger than 100,000 btu/hr we thinking...
  10. farid2176

    NFPA- Storage water size for Sprinkler system

    Thanks MechEng2007, Do we need to include hose stream allownce for storage water calculation
  11. farid2176

    NFPA- Storage water size for Sprinkler system

    We are not trying t design the system, the project is in planing phase we need to allocate the space for storage tank, i like to have some storage tank size the fire protection will be performance spec item Thanks any way
  12. farid2176

    NFPA- Storage water size for Sprinkler system

    Thanks for the quick response the table you mentioned will give me the Hose allounce and the duration. should i consider density/area curve to figure out the water demand for sprinklers. have you used this density/area curves before, can you explain how to use these curves Thanks I appreciate...
  13. farid2176

    NFPA- Storage water size for Sprinkler system

    We are desiging a builidng in remote area. this builing have boarding, labs and little office spaces i think the majority of builindg will be light hazard area. There is no city water in this area and we have to provide storage tank for sprinkeler system. I am woundring if any body can point out...