  1. eleceng85

    Minimum signal stringth for sending SMS

    Hi i wonder if any one can help me to know the minimum signal stringth & power needed to send a SMS message if u can support your answer by a document. thank you so much
  2. eleceng85

    Minimum signal stringth for sending SMS

    Hi i wonder if any one can help me to know the minimum signal stringth & power needed to send a SMS message if u can support your answer by a document. thank you so much
  3. eleceng85

    Generator remote monitoring and control

    Deep sea technical support reply but it is disappointed :-( : Deep sea technical support :You can use any modem for the PC side, we recommend the Multitech Global Modem ZBA or the Wavecom Fastrak as we know them to work well. The SIM card in the GSM modem must support CSD (Circuit Switched Data)...
  4. eleceng85

    Generator remote monitoring and control

    Good Idea i like the bang part [thumbsup]
  5. eleceng85

    Generator remote monitoring and control

    Hi i need to monitor and control the generator by PC via GSM (i choose the gsm bcoz the genset in the desert, away 100 km from the control room) the generator's control module is DSE7510, i have also GSM modem (Wavecom fastrack M1306B) and pc software for monitoring. my inquiry is do i need...
  6. eleceng85

    WYE to Double delta converting

    thank u so much for help
  7. eleceng85

    WYE to Double delta converting

    Hi all i has 3 phase wye connection 400V LL, 230V LN, 30KVA i wanna make it single phase i read in the generator manual the best way to make it single phase is the double delta. my question is: when i make the connection double delta does this decrease the rating power ? or the generator will...
  8. eleceng85

    11 kv/400 v transformer phase problem !!

    actually the terberg "synch. module" phase voltages was L1=0,L2=680,L3=400 but i measured it by voltmeter: L1L2=400,L2L3=400,L1L3=400 .... and according to ground L1=0,L2=400,L3=400 !!! does any one tell me y this transformer act like that ??!!
  9. eleceng85

    11 kv/400 v transformer phase problem !!

    as well as every generator sensing missed phase .... low voltage side for every transformer is delta
  10. eleceng85

    11 kv/400 v transformer phase problem !!

    i tested it according to the ground and according to the other phase even i touch it by bare hand and bare feet !!! it's voltage 0 zero... that's really make me sick :(
  11. eleceng85

    11 kv/400 v transformer phase problem !!

    we faced a problem in power plant consisted of 4 diesel generators 400 v synchronise togather and every generator connected to 400v/11kv delta/wye Transformer the synchronisation in low voltage side (400v) when we turn on the first generator it's transformer rise up the voltage to 11kv and this...