Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: oriol
  • Order by date
  1. oriol

    step name / element number from type / python

    Hi! I was wondering if any of you could tell me the python comands to get the step names from an odb file. Also, I would really like to get the numbers of the elements that have specific and same element type, from parts or instances in the assembly. Is it possible to script it? Thank you! Oriol
  2. oriol

    Naming a partitioned cell

    Sure, Nileo2005. But do it just once. Then create a set and you will be able to reach it whenever you want much easly. Oriol
  3. oriol

    .dat error

    Thanks Jlog50 and corus. In fact I'm running it remotely. The computer node were I'm trying to submit the job has 32Gb of memory. That is why I though could be related with some setting in the .env file. Perhaps all files together during pre-processing exceeds 32Gb and the unit10 'file' is the...
  4. oriol

    Naming a partitioned cell

    Check in the 'Selection toolbar' if, while selecting the cell, you have the option 'Cells' or 'All'. Oriol
  5. oriol

    Abaqus 6.10 - Abaqus/CFD and Abaqus/Standard Co-execution problem

    Hello Jlog50, In fact I followed step by step the example from the presentation of abaqus 6.10 in simulia but anyway, as far as I understand we have: - For the stuctural model: ** Interaction: Int-6*Co-simulation, name=Int-6, controls=Int-6_Ctrls, program=MULTIPHYSICS*Co-simulation Region...
  6. oriol

    .dat error

    Hi! I'm trying to perform a simulation with a quite, lets call it, big model. The fact is that while performing the pre processing the simulation fails and I get a message in the .dat file that says: ***ERROR: THE FILE SIZE EXCEEDS THE 16 GB LIMIT ON UNIT 10 Does any one know what can be...
  7. oriol

    Naming a partitioned cell

    Hi, you have to create a set containing the cell. Then, using "create display group tool", you will be able to selected more easily. Oriol
  8. oriol

    Abaqus 6.10 - Abaqus/CFD and Abaqus/Standard Co-execution problem

    Well, I was testing quickly how is co-simulation working on an example last week. I succeeded runing it but still a lot to do in order to get what I really want but if it helps, here you go: .inp for CDF: *Surface, type=ELEMENT, name=_PickedSurf7, internal __PickedSurf7_S4, S4 __PickedSurf7_S6...
  9. oriol

    QUESTION ABOUT PYTHON SCRIPTS

    What loki3000 wanted to tell you, I think if not correct me, is that in abaqus.rpy file located in your working directory, you can see every python command abaqus executes when you do something clicking on the abaqus interface. In this way, you can script and then to modify some values... and...
  10. oriol

    Temperature value visualization

    Hello! I performed a stress simulation which has as a predefined fied temperatures from a previous heat transfer analysis. Does anyone know if I can see/visualize the read temperatures from the stress.odb file? Using abaqus for results visualization. Thanks a lot! Oriol
  11. oriol

    Zero reaction force

    Ok! Will check that. Sorri Niranjan :) Oriol
  12. oriol

    Zero reaction force

    Hi, I guess it depends how you modeled the surface. I'm modeling contact with a surface as well and my surface is a 3D analytical shell. Then I made it rigid because I didn't care how the surface itself reacts or deformes but how is the solid that gets in contact with the surface. The contact...
  13. oriol

    restarting an analysis

    Hi! I will need to cancel one job because I'm gonna run out of memory. I do not want to change anything from previous analysis, just to use more computer-nodes to perform the analysis. I have read the documentation but one think isn't clear for me: The new .inp file that I have to create, do I...
  14. oriol

    RP tied to Part: How?

    Thanks! You helped me a lot. Regards
  15. oriol

    RP tied to Part: How?

    well, it would be a possibility but it's a bit too dificult at the point I'm now in this project. thanks anyway. I think a possible solution will be to add a friction coeffitient in the contact property. i guess i understood wrong the wires funtion. i thought i could keep to points from...
  16. oriol

    RP tied to Part: How?

    Hi! I've been trying to model contact between to parts that initially they are in contact and they must continue in contact after aplying gravity load. They are not welded but tied using clasps. I don't want to model clasps so I was thinking to keep them together with a wire (tie) using RP on...
Back
Top