@saplanti
The skin temperature to be maintained at 50 deg. cen.
@IRstuff
I am doing back calculation for an old design of my company product. The thickness and thermal conductivity data of the insulation materials are available in the old design. However, shell temperature assumed, amount of...
Hi,
I am designing a electric heating furnace having different layers of insulation following by a outer metal casing. Its a 150 kW furnace. I have the thermal conductivity & thickness details for all insulation layers. I would like to calculate the outer skin temperature of the casing. What is...
Amount of heat transfer 'Q' depends upon the thermal resistivity/conductivity of the materials. However, once the material reaches it maximum heat holding capacity it transfer all heat. Hence, 'Q' should be same for A and B materials.
But the heat flux/rate of heat transfer would be different...
Hi Guys,
Can any one answer the below questions?
1. Whether liquid details entered in PV Elite gives any impact on thickness calculation?
2. If liquid details are not entered by designer in PV Elite, what details will be considered automatically for thickness calculation?
3. Whether the design...
Hi,
I am designing a vessel having support rings (top & bottom) attached to cylindrical part of vessel. The two continuous rings having 2 nos. of gusset plates at 3 points.(Beneath this 3 points pipe legs will be there where this vessel will be landed.
In PV Elite lug input data window "weight...
Thanks guys..!
The vessel is to be lifted vertically. I would like to design it in PV Elite itself. 3 nos. lifting lugs are required at 120° each on top dished head.
Is it possible to do the design in PV Elite on the top dished head?