  1. esfo71

    Compressed Air Sizing

    I uploaded the proposed layout for the compressed air network. Any suggestion would be appreciated. Some sample calculations or methodolgies based on the drawing would also be appreciated to get me going. Thank you...
  2. esfo71

    Compressed Air Sizing

    Hello, I am currently sizing a Compressed Air Network (Compressor CFM, HP, and Line Sizing) for a plant which has air service stations and pumps that are run by air. There are 13 Oil Supply Pumps (80 CFM @ 75 PSI each), 20 Waste Oil Return Pumps (40 CFM @ 75 PSI), and 31 air service stations...
  3. esfo71

    Compressed Air Sizing

    Hello, I am currently sizing a Compressed Air Network (Compressor CFM, HP, and Line Sizing) for a plant which has air service stations and pumps that are run by air. There are 13 Oil Supply Pumps (80 CFM @ 75 PSI each), 20 Waste Oil Return Pumps (40 CFM @ 75 PSI), and 31 air service stations...
  4. esfo71

    P&ID

    Hi, I started a new job in industrial consulting engineering. I am working on a gold mine development in Ontario. I was given a PFD of a Potable Water Distribution System and need to produce a P&ID and then a GA (General Arragement). The water is taken from a lake through inlets and brought to...
  5. esfo71

    Outdoor Air Calculation

    You're right tys90. I was referencing an old version of ASHRAE...I believe 1990...it was just for a quick calculation. Your method is more up-to-date.
  6. esfo71

    Outdoor Air Calculation

    Thank you KiwiMace!!! You are correct. The OA will be mixed-in with the room return air (271 CFM 75'F / 50%RH of Room air mixed with 100 CFM of 90'F DB / 75'F WB of OA) where it will then be treated by a fan-coil unit (which is located in the ceiling space of the room) and then redistributed to...
  7. esfo71

    Outdoor Air Calculation

    Hello, I have a question with concerns to Outdoor Air calculation. I have a Dictation Room within a hospital that is being reconfigured by the architects. This room has no exterior walls and is in the basement. The Volume of the room is about 3100 cubic feet and the Floor Area is about 400...
  8. esfo71

    Asbestos' (or Asbestos-Cement's) Corrosion Resistance agaist Salt

    Hello, I was wondering if somebody can help me out with a question I have with concerns to Asbestos. Would anybody have a Chart that indicates the Corrosion Resistance of Asbestos (or Asbestos-Cement) against Salt? If so, I would greatly it if you could send me a copy or direct to me where I...