  1. Clareok

    Cast spool with flanges - Unlisted material A494 CW6MC -N26625

    Hi - have short spools 6 & 8" to be casted from A494 CW6MC with both ends formed into 600# rated flanges. This material is not listed in B31.3, II D, B16.5, B16.34 From ASTM A494 i can get the tensile & yield values but struggling to elevated temperature allowables & P/T ratings. What options do...
  2. Clareok

    Calibration loop spools for internal use

    Thank you all for your input, its always good to hear from like minded ppl. Design pressure of the pipeline is 12 bar, hydrotesting to 18 bar. I wonder what the worst failure could be, assume a dribble leak, or could there be a major blowout occur.. i dont know. The special flange is real...
  3. Clareok

    Calibration loop spools for internal use

    8" Sch 40 has an ID of 202.74mm, so we can roll 2/3 plate to this ID +/-, but a close as possible to this. Agree you state the mill tolerance, but we try to get close to the theoretical. 6m of 8" sch 40 304ss is approx €5k. We can get this rolled and welded for fraction of this (welder not code...
  4. Clareok

    Calibration loop spools for internal use

    Totally agree, in that we intend to hydrotoest. The reason we want to roll pipe is to save money. As its a calibration loop, the ID is critical. Typically need the ID of 8" sch 40 but that is very expensive in 304ss. We can get the same ID from formed pipe (rolled or folded) making it alot...
  5. Clareok

    Calibration loop spools for internal use

    Correct, we are in the EU. We will not be putting this on the "market", therefore i dont believe it needs CE marking.. its for internal use only.
  6. Clareok

    Calibration loop spools for internal use

    We have a pressurized calibration loop where we want to reduce cost for spool sections. We want to be in compliance with B31.3 generally. As we need to have inner diameter to a certain dimensions (8" sch 40), we can get 2 or 3mm plate rolled to this ID. To be in compliance with B31.3, do we...
  7. Clareok

    Transfer heat numbers

    LittleInch - thank you for your detailed reply. Much appreciated.
  8. Clareok

    Transfer heat numbers

    Hi all. My company builds flowmeters using short pipe lengths (A106, A312 etc). Is there a standard that states the heat number must be transferred between the new pipe from the original pipe section. Of course common sense should prevail but I’d like to know if there is an international...
  9. Clareok

    Thermal Fuse for panel heater

    When you say not to uprate the temp rating, do you mean the temp or the amps? could i use the 65C 10 amp alternative for my application, 65C 4 amp?
  10. Clareok

    Thermal Fuse for panel heater

    Attached photos http://files.engineering.com/getfile.aspx?folder=21d5ba25-a39a-48f0-8fd1-ea89479b90fd&file=IMG_2479.JPG http://files.engineering.com/getfile.aspx?folder=f18b2f93-e77f-45fb-b016-5119a41953ae&file=IMG_2482.JPG...
  11. Clareok

    Thermal Fuse for panel heater

    Hi – last year a purchased a panel heater but since it has stopped working, I have established that it is the thermal fuse that is gone. I cannot find on the internet the same fuse, so I need some help to understand these components. Since I cannot find the exact same fuse, I need to figure how...
  12. Clareok

    Norsok M-650

    Hi I’m relatively new to Norsok requirements on oil & gas equipment. My understanding is that material to be used shall come from a Norsok Qualified mill according to M-650. This mill would need to have a QTR certificate for each type of material. I’m being told that if I get the steel from a...
  13. Clareok

    ASME B31.3 "Hill side connections" & ASME VIII Div 1

    Scenario: Design Code B31.3. Branch connection to pipe run is hill side. Code Clause: 304.3.1 (b) (4) “the axis pf the branch intersects the axis of the run” Problem: B31.3 does not consider hill side branch connections. Solution: Refer to 304.7.2, but this does not allow calculation to ASME...
  14. Clareok

    Linear screw actuator

    Yes that is correct, thanks for your response. i might have to change the gear ratio for correct motor selection. Thanks for your response. Have i calculated the correct torque? Does 0.7Nm sound correct?
  15. Clareok

    Linear screw actuator

    Due to space restrictions I wish to design a linear actuator using trapezoidal screw, see attached sketch. Travel required=730mm Required time=25sec Motor Speed=584rpm Mass=45Kg l=Screw pitch=3mm dm=Mean pitch diameter=12.45mm f=Friction coefficient=0.15 F=Load=441.45N Calculated torque...
  16. Clareok

    B31.3 v Section II D Pipe Design

    Trying to design a piping system with duplex pipe material S31803 A928 CL1 to ASME B31.3. B31.3 does not list the stress values for this material. Is the correct procedure to use a similar material in B31.3, say A790 S31803 or should one refer to ASME II Part D? Per the example above if one...
  17. Clareok

    FM / CSA Coaxial cable

    Hi, Our company provides equipment with armooured coaxial cables (RG62 A/U). We have a requirement to supply our equipment into a hazardous area, that is not ATEX but FM/CSA certified. We can procure CSA certified armoured cable glands, but im not sure if its possible for procure FM/CSA cable...
  18. Clareok

    Cr5Mo pipe material?

    Hi There. I've a new project with MOC to be Cr5Mo, what is ths material in terms of ASTM? Product will be used in China. Regards J
  19. Clareok

    Radiographic requirements for Annular Plates

    Cant help you Knat, having a simlar problem in reading this section of API 650. It states radial joints, we dont know if these are the joints in the bottom end or the joint of the shell to the base. Any help would be great j
  20. Clareok

    3GB Switch Enabled but 2011 not using it.

    Thanks TigerGeek, I've aslo gone back to normal mode, having the same video problems.. so frustrating. Reckon its my older machine (Dell M90)with the newer IV software...