No, its not a truss, elements have fixed connections.
If I connect beams at their centroids, not only I am using more material than in reality (and more self weight in the model), but am I not considering more section strength also?
I want to model a connection between two CHS and one SHS in FEM beam model.
How do I make the model to consider that the SHS does not reach the center of the CHSs, but only their exterior surface?
I attach two possible model solutions. I believe the first one is unrealistic since the length...
I am calculating a padeye with a shackle, in which the force coming from a cable is deviated a certain angle in the both represented views (vertical and horizontal deviation), due to cable misalignment.
Does the fixed surface in red have a torsion moment?. I can easily find a tension force...
Yes, I know very well the statics and linear theory.
But what happens in reality? Doesnt the bolt have plastic deformation on only one side? How do large deformations and nonlinear geometric analysis benefit one support over the other? Is there a nonlinear FEM example that proves it?
I have a rectangular steel plate with a bolt in the middle and pinned supports at each extreme.
The bolt transmits a force to one side of the plate. Theoretically (following linear statics), both supports have the same reaction force value. But is this tru in reality? Doesnt large deformations...
Four meters. The impact is an increase in nozzle required nozzle thickness as per UG-37.
The question is simple, should I use design or test pressure in UG-37 / UG-45 when test pressure is 3 times the design pressure as stated by client?
I read UG-99 and still don't known whether if I should use design or test pressure in UG-37 / UG-45 when test pressure is 3 times the design pressure as stated by client.
Yes, UG-37 requirements of nozzle thickness are greater for test pressure than design pressure.
Yes, that's the client...
I dont know that.
But since test is performed right after assembly, there is no corrosion yet. I calculate nozzle pads and thicknesses with 3mm corrosion, so I believe Im on the safe side. Still, I would like to know if I have to justify the calculations with test pressure in ASME.