  1. JigarJoshi

    Level Measurement through ERS- Electronic Remote Sensor (Rosemount New Technology)

    @danw2 : Thanks for your answer. It will help me to clear my doubt. but plz post if you find any other strong data relate to ERS. Thanks again.
  2. JigarJoshi

    Level Measurement through ERS- Electronic Remote Sensor (Rosemount New Technology)

    @djs : I have already read all related Documents generated by Emerson on ERS system. Even I had a conversation with Emerson Application Engineer. However, I was informed by one of my very experienced design Engineer that ERS can be used for Interface. This is the reason why I need confirmation...
  3. JigarJoshi

    Level Measurement through ERS- Electronic Remote Sensor (Rosemount New Technology)

    Dear All, Do anyone have idea about the application of ERS transmitter in Interface level measurement . I want to use this transmitters for interface level measurement. I searched on the internet but cannot found strong relative data. Though some Engineers are telling that it is possible to...
  4. JigarJoshi

    Seat contour / Linear contour / full contour, Multi hole and Balanced type plug in control valves

    Thanks danw2... I have read the control valve handbook and soursce book for Pulp and paper but let me sink my beak in other books also. thanks for your response.
  5. JigarJoshi

    Seat contour / Linear contour / full contour, Multi hole and Balanced type plug in control valves

    Can Anyone tell me when should I use Seat contour / Linear contour / full contour, Multi hole and Balanced type plug in control valves?
  6. JigarJoshi

    Flushing connection requirement

    Can anyone tell me that Why and for which Process condition Flushing connections required(For Diaphragm Seal Transmitters)??
  7. JigarJoshi

    Control Valve and On off Valve Designing data requirement

    Dear all, Can Any one suggest me any book on web or Link , where I can find all Basics for Designing Control valves, On- Off valves?? I want to make myself aware regarding all selection and basic parameters..I have gone through Emerson- Control valve Handbook but still i want to know more...
  8. JigarJoshi

    Use of Seat contour / Linear contour / full contour, Multi hole and Balanced type plug in valve.

    Can Anyone tell me when to use Seat contour / Linear contour / full contour, Multi hole and Balanced type plug in control valves?