all..
i got requirement to provide the air compressor for wellhead control panel. This compressor will be used for pneumatic actuator for valving in Well Head Control Panel.
Are the any guidance for selection which type of air compressor suitable for this purpose, also also the common size for...
hi dear..
i need advise for materrial selection for h2s removal pressure vessel for gas
this pressure vessel will be used for h2s removal which the inlet gas contain sulfur 150 ppm
the pressure inlet is 15 psig, and the gas temeprature 125 deg.F
ijust thinking to use carnon steel with suitable...
hi McDermott1711's
yes you are right.. i am mix up with the discharge line which connect to the pump and the pressure is 20 bar
this is the intake line, and only hhydrostatic pressure from sea level
thanks for your info
hi MJCronin..
keep calm and stay cool
it is technical discussion, no more
see my information detail on the picture ..
https://files.engineering.com/getfile.aspx?folder=821a38b1-6298-41fd-a8d5-b8d0f4d7c4f9&file=inlet_pipe_to_engineering_tips.jpg
thanks for all response
the duplex nozzle pipe will connect to the pipeline with the operating pressure about 20 bar
this is sea water line supply to the plant. The pipe line looks is FRP
Sea water intake basin will be built with the concrete, which is the duplex pipe will be inserted in the...
hi mk3223..
thanks for your info
i just checked it, and the rating looks not ASME standard, this flange according to DIN standard
anyway thanks for this info
i am designing sea water intake pipe, and will use duplex material,
The pipe diameter is 2000 mm, and will use pipe class 300#
is there any dimension standard for flange, rating 300# and bore size 2000 mm ?
please advise for flange material applicable for this service
regards,
rudiawan
The pumps is vertical turbnine and the suction us submerged, hence no issue regarding priming
individual flow meter not available, but speed of VFD are controllabe by PLC / DCS
(see on the attachment)...
hi littleinch ..
The 4 pumps supply sea water into the pipeline which the diameter is 60 inch, into the sea water tank
the length of the pipeline about 6 km
the pipeline provided with surge control valve to maintain surge pressure due to back pressure
regards
rudiawan
dear all..
i am designing the Sea Water Intake pump which the 4 pumps will be operated parallel, and 1 pump will be as stand by pump
The pump data as follows :
Type : vertical turbine pump
Flow : 5000 m3/hr
Head : 20 meters
Electric Motor : 2500 KW, the motor provided with VSD (variable speed...
hi all..
apologize to attach the attachment..
https://files.engineering.com/getfile.aspx?folder=63e74b81-5787-4451-b4a5-7a745f2f61ea&file=acess_stair_on_tank_roof.jpg
hi all..
i have access stair between tank which sit on the tank roof structure (see on the attachment)
The tank diameter is 38 meters, and self supported cone roof tank
tank height is 19.5 meters
Thanks for your advise
regards,
rudiawan
hi hturkak..
thanks for your respond,
this pipe basiccaly connect from sea water intake, which the distance is about 5 km
the pipe is layed on the sea bed and provided with concrete weight for some distance.
The pipe material is HDPE
what we concern is when we simulate with seismic case and the...
dear friend ..
we have the project which the 30 inch pipe penetrate to the wall of sea water intake basin.
The concrete wall thickness is 750 mm
we need to get the allowable maximum load on this point (pipe that penetrate to the wall)
is there any standard for our reference
if using puddle...
all..
we are using overflow weir box on the water tank (designed follow API 650)
as seen on the attachment, the overflow pie diameter 1s 1200 mm
The boz size is 3m x 3m x 3m
can we evaluate the load on the tank shell that is connected with overflow box using nozzle pro..
peaase advise if other...
friend..
i would like to do sizing the Pressure relief valve (PRV)
is there any rules of thumb how much percentage of flow to PRV compared with the flow of main line ..
thanks in advance
rudiawan
all..
we are doing pipe routing for the pipe connect to tank, the data as follows :
- the diameter of pipe connecting to the tank is 1500 mm
- tank diameter 38000 mm
we have performed the pipe stress and get Force and Moment on the tank nozzle
My questions is how to evaluate the force and...