Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Nzhou
  • Order by date
  1. Nzhou

    Belt Furnace Contamination

    Yes, contamination can occur with belts as time progresses. Furnaces need to be equipped with a steel brush to clean large unwanted particles. Another device such as an ultrasonic cleaner needs to be installed in the furnace to further clean smaller particles that could affect the quality of...
  2. Nzhou

    Optimizing old belt furnace equipment

    A computer system for a belt furnace usually consists of not just the PC but communication modules (to communicate between the PC and the temperature controllers) and software. The PC needs to have certain ports available, RS232/USB. While it is technically feasible to use your regular PC (and...
  3. Nzhou

    Adjusting Height of Belt Furnace

    The height adjustment is based on the manufacturer and you should refer to them. Furnaces are adjustable up to around 10 cm up and down in my experience. Nick Zhou Torrey Hills Technologies, LLC. http://www.beltfurnaces.com/
  4. Nzhou

    Adjusting Height of Belt Furnace

    New furnaces can be height adjusted according to the required needs. On the bottom of the furnace are legs that can be rotated and adjusted to certain heights. Nick Zhou Torrey Hills Technologies, LLC. http://www.beltfurnaces.com/
  5. Nzhou

    Heat treatment in a conveyer furnace

    Yes, the 500C zone can affect the 150C zone, if there are any changes in the temperature of that particular zone, more or less power is directed to that particular zone by an automatic controller. A PID precision is +/- 1?C and a cross-belt temperature uniformity is around +/- 4?C for a 1000mm...
  6. Nzhou

    Heat treatment in a conveyer furnace

    In a belt furnace a combination of PID controllers and thermocouples with auto-setting parameters are used. The thermocouples are placed in every single zone and slightly above the belt to give the most accurate feedback to a computer control system.

Part and Inventory Search

Back
Top