  1. ars001

    Rigid Insulation Structural Values

    Well, long story short. I have a situation where I'm supporting about 6" of soil from going underneath a continuous grade beam (washing underneath the grade beam) with rigid insulation. I just want to make sure it won't snap off.
  2. ars001

    Rigid Insulation Structural Values

    Does anyone have any allowable bending stress values for rigid insulation? Thanks
  3. ars001

    Doube Angle Column Intermediate Connectors

    I did read that information at the beginning of the chapter but the connectors shown on the load tables still makes no sense. I understand that you can use less by computation.
  4. ars001

    Doube Angle Column Intermediate Connectors

    The Table 4-8 (double angles in axial compression) in the AISC 13th addition steel manual gives the number of connectors needed between angles. Can somebody explain to me why the number of connector say for like a 2LL6x6 column is 2 no matter if you have a 2' long column or a 40' column???
  5. ars001

    Overturning Moment Factor of Safety

    Thank you. That's kind of what I thought.
  6. ars001

    Overturning Moment Factor of Safety

    StructuralEIT- I guess thats the question I'm asking. Is the IBC saying the overturning F.S. is now 1.66666 (.6 dead load) or does is still say somewhere 1.5 (2/3 dead load)?
  7. ars001

    Overturning Moment Factor of Safety

    The good old UBC use to allow us to design shear walls using 2/3 dead load of the wall for calculating overturning moment. Now it seems the new 2006 IBC doesn't specifically specify this anywhere that I can see. So does that mean I'm back to the basic load combination .6D + W ? Thanks
  8. ars001

    Simplified Wind Procedure for Buildings with parapets.

    I think some engineering judgement has to be used in this case. Obviously most buildings have parapets. But does this constitute having to design a building per the anayltical procedure because you have say a 6" high parapet? Probably not. The same thought process could go into buildings...
  9. ars001

    Multi story wood structure stud wall plates

    I think I go around and around with this situation everytime I look at my detail. I have a 4 story wood structure (hotel) that is framed with 2x6 stud walls and 24" deep pre-engineered roof trusses. My questions lies at each level where the stud wall sits on my trusses. I usually provide a...
  10. ars001

    Why does the IRC differ from ACI requirements

    I've alwayed wondered why the IRC (table R404.1.1 (5))doesn't follow the minimum reinforcing requirements as set by the ACI. Can somebody elaberate?
  11. ars001

    Allowable defelction for Spandrel Beam bracing masonry

    Keep in mind that the L/600 limit is only required when supporting unreinforced masonry and brick. I've had great success using something less stringent for supporting reinforced masonry.
  12. ars001

    Design of Headed Anchor Bolts

    KBVT- My loads are much greater than what I can accomplish with an unreinforced concrete. I need to transfer my loads from my anchor bolts into my steel change of my concrete pier.
  13. ars001

    Design of Headed Anchor Bolts

    Can anybody lead me to a good reference for design of headed anchor bolts in reinforced concrete piers? Thank you.
  14. ars001

    Cantilered Column Embedment Into Masonry Pier

    I'm designing a monument sign which has a steel column on each side which is embeded into a masonry pier at grade. The columns obviously cantiliver. How far do I need to embed my steel column into my masonry pier? The masonry pier sits on a footing 3'-4" below the surface. I believe the...
  15. ars001

    Slab of Grade Reinforcement Coverage

    Sounds good. I guess I need to open my eyes. Thanks
  16. ars001

    Slab of Grade Reinforcement Coverage

    SteveGregory ACI reads "concrete cast against and permanently exposed to the earth". Isn't compacted granular fill considered earth?
  17. ars001

    Slab of Grade Reinforcement Coverage

    If I am using #3 bars at 18" o.c. in my slab of grade am I required to provide 3" of cover as ACI 7.7 specifies? Or are concrete slab on grades a different ball game than what 7.7 covers? I wouldn't usually worry about it but I'm using it as a diaphragm so technically I suppose its a...
  18. ars001

    Parking Garage Live Loads

    So what I'm hearing is I design for either the uniform load or the point load but not in combination with one another?
  19. ars001

    Parking Garage Live Loads

    According the IBC 2006, I need to design for a 40 PSF uniform live load or 3000 psf concentrated live load for passenger vehicle parking garage floors. Is it as simple as designing for one or the other? Do I use a combination of the two? Say I have a simple span beam 30' long. One load case...
  20. ars001

    I'm Moment Frame Happy!

    Yeah, I agree. I probably should model it in Risa. I was trying to simplify it as much is possible and try doing it by hand. Obviously its not that simple. I agree there is alot of strenght and stiffness stuff going on with cantilevered columns and so forth. I want to make sure everything...