  1. KMP04

    Labyrinth Oil Seal ring alternative

    Thanks for the comment JP. Actually, this damaged laby seal was only discovered during bearing dis-assembly, there was no issues raised with leaking seals. The only difference in the seal design is changing of ring materials...Aluminum vs. Brass. My concern is protecting the condition of the...
  2. KMP04

    Labyrinth Oil Seal ring alternative

    Hi, I have a large 3ft diameter turbine bearing that has a damaged non-contact mechanical Labyrinth seal that uses multiple brass rings in the assembly. My machine shop is proposing to replace the lab seal with a 1 piece aluminum housing out of 6061-T6 with the grooves cut directly into the...
  3. KMP04

    Lake ice design load expected on a pipe dock

    Hi, I'm currently designing a permanent pipe dock to be installed at the cabin...In addition to considering buckling, I need to consider ice loading...Does anyone know what the design pressure due to ice loading on marine structures is? Is this load dependant on the body of water (My location...
  4. KMP04

    Why are "low hydrogen" diffusion weld consumables hard to find?

    Hi Guys, Our design group has recently provided a criteria regarding the use of SMAW electrodes and MIG wire consumables with the restriction of less than 16ml/100g of diffusable hydrogen and we are trying to conclude if the consumables we have in stock meet these specs. BLUE MAX 309LSI SS...
  5. KMP04

    Cavitation repair for cast steel hydraulic turbine runner blades

    I'm looking for some feedback in regards to standard cavitation repair practices for turbine runner blades in the hydro electric industry. There are various opinions regarding pre-heat of runners prior to a gouging operation and welding Stainless overlays onto cavitated areas. Typically our...
  6. KMP04

    PTFE Pump packing (stuffing box) sizing problem

    Thankyou everyone for your comments. Packing was installed with leakage kept to an acceptable level! Regards, KMP
  7. KMP04

    PTFE Pump packing (stuffing box) sizing problem

    PROBLEM: Unfortunately site has no more 1.5" square PTFE braided packing in stores for their water seal stuffing box, located on one of their hydraulic turbine units. Shipping is 7-10 days and they need the unit online ASAP. The question is, can we compress 1.25" square braid (in stock) to fit...
  8. KMP04

    Buckling Calculation for Cast Iron link

    Drawoh, I am actually replacing the old cast iron links with steel. Regards, KMP.
  9. KMP04

    Buckling Calculation for Cast Iron link

    Thankyou Everyone for your feedback. Regards, KMP04
  10. KMP04

    Buckling Calculation for Cast Iron link

    I recently have been performing design calculations for a small cast iron link with an applied bearing load (pins)on each end, compressing the link. 2.375 OD bushings are spaced 6" center to center at the link ends. cross section of the link 3" x 1.5" thick. Using Eulers formula for pin ended...
  11. KMP04

    Cast Iron Turbine Casing Repair

    teb1, give me a call 204-477-7900 to discuss.
  12. KMP04

    Cast Iron Turbine Casing Repair

    Yates, This is a 100yr old grey cast iron casing. Unfortunately I don't have confidence that a weld repair will provide a successful fix. We are currently in contact with several Cast Iron repair companies that specialize in this service. If all else fails, I may have to fabricate a new...
  13. KMP04

    Cast Iron Turbine Casing Repair

    Thanks metengr...Where can I find more information on metal stitch mechanical repairs? Regards, KMP04
  14. KMP04

    Cast Iron Turbine Casing Repair

    Can anyone recommend repair options for a 12" long crack on a 4" thick cast iron turbine casing? This 17 ton component is located inside a turbine pit which holds a dual francis horizontal runner/shaft assembly. Will a weld repair be successful if preheat is not possible? Thanks.
  15. KMP04

    Prevailing Torque "Stover" Nut?

    Thanks CoryPad I figured that the stover nut did not require the same thickness than a nylock, since it did not have the 1/4" thick nylon portion on the top face...Do you know whether it has better or worse breaking torque than the nylock? Are you suggesting that these type of nuts only be...
  16. KMP04

    Prevailing Torque "Stover" Nut?

    I am considering using a 1 1/4" nylon lock nut for my application, however, due to thread engagement limitation I would like to consider the Prevailing torque nut. I am unfamiliar with this style of nut. Can anyone provide input on how well it works?
  17. KMP04

    Weld preheat for 4130 QT Steel?

    Hi metengr; This is a solid shaft, 4ft. long, Hardness = 22HRC, two welds around shaft circumference - spaced 10" apart , Weld size is 3/8". Shaft was water quenched from 1600F; tempered at 1225F. Thanks for your input.
  18. KMP04

    Weld preheat for 4130 QT Steel?

    What is a recommended preheat and post heat temperature for welding (7018 electrode) around a 10" dia. 4130 steel shaft (Quenched and tempered)? I have read that a suggested preheat is in the order of 300 deg.C but have not found any post treat recommendations? Any other precautions I should...
  19. KMP04

    Torque Calculation for Tapered Bolts?

    My past experience with removing tapered bolts from a coupling flange was that they were torqued so tightly, we destroyed them while attempting removal. Now that new bolts have been fabricated, I am looking for any industry standards or calculations for taper bolt applications... Can anyone...
  20. KMP04

    Calculating elongation of bolt, at thread engagement?

    In order to ensure that the proper bolt preload is achieved, I have calculated a corresponding bolt elongation using the following formula: Total Elongation = sum of [(PxL)/(AE)], at various cross sections of the bolt. I found that the actual Torque value was less than what I estimated it...