Hi, thanks for your response.
I am using solid elements of 1mm x1mmx 1 mm mesh size.
I am attaching two pictures:
1. The picture of the bolt after adding the bolt load (7 N).
2. The picture of the bolt after the post-buckling analysis where imported geometry from the bolt load file was...
Yes, I agree.
I modeled it for only one benchmark analysis, for checking.
The analysis provides correct results when bolt pretension is not modeled.
With the pretension, I am getting an artificial increase in the column capacity and also an incorrect failure mechanism that does not match my...
Hello,
Using a dynamic explicit solver in Abaqus, I am performing a post-buckling quasi-static analysis of thin-walled (2 mm thick) cold-formed steel C sections connected to a U section at both ends.
As per my model geometry, the U-section is connected to hot rolled steel loading plates (12 mm...
In the post-buckling analysis, imperfections were imported from the buckling analysis by the edit attribute function in Abaqus CAE in the input file. Is it because of importing the imperfections?
The support plates at both end and the loading plate at the top was created as discrete rigid plate elements. The reference points were created at the part level. I have used three seperate discrete rigid plates as loading plate and the two support plates.
Thanks, for your response.
I applied the boundary condition at the reference points of the rigid rectangular plate elements.
What should I do to get rid of this error?
Hello,
I am doing a three-point bending analysis of a cold-formed steel beam. In the post-buckling analysis using the Abaqus explicit solver, I got the below error:
in keyword *BOUNDARY, file "Job-18.inp", line 55500: Unknown assembly id 2
I have applied boundary conditions at the reference...
Hello,
I am performing numerical simulations of the axial-compressive test of cold-formed steel-lipped channel sections (stud) connected to a small length of U sections (track) at both ends with self-tapping screws under axial-compressive loading (displacement-controlled loading along the...
Thanks for your response. I am very new to contact analysis in Abaqus.
Could you please explain:
1. Does Abaqus provide CPRESS per node? I should create a node group on the Usection web to check the CPRESS?
2. What is meant by COPEN and STATUS?
3. How can they help me determine the right...
To Add to my query:
Could you please provide me reference some more materials (articles or books) on how abaqus calculates contact pressure so I can refer to it?
Hello,
I am performing a compression test of a Cold-formed steel channel column connected to the track (U section ) at both ends.
I use a softened contact formulation in Abaqus explicit for normal behavior (Scale factor: using general contact explicit). I am also checking so that there is no...
Hello,
I am simulating a compression test on a cold-formed steel-lipped channel column (stud). The column is connected with a small length of a U section (track) at the top and bottom.
There is a gap between the stud and the track, and I have modeled the gap.
Initially, I defined the normal...
Thanks, I am doing a sensitivity study with k values, as you have advised.
Could you have some idea of the k value from contact pressure?