Depressurization within a vessel results in adiabatic cooling. Lowered temperature (even negative) is expected. At the outlet of a valve, the gas could either warm or cool, depending on the Joule-Thompson coefficient. These are both described in most textbooks about thermodynamics.
As a...
How can I reverse convert an executable file to excel file? That is, this exe file was previously an xlsx converted to exe. How do I reverse it to xlsx?
LonnieP,
It seems that you are new to Excel VBA programming, so the best tip is to use the "Record Macro" function found in the Developer menu or Developer tab. Click "Record Macro", change the color of a cell, print, insert a row, copy and paste, or any other activity and then click "Stop...
Here is a good tip: Set your Macro Security settings to "Disable all macros with notification". For unknown files, open the VB editor and review all the code. If there is something you do not understand or looks malicious then simply close the file. If it looks fine then accept the security...
MESSADAA,
I would consider both. That is, pumped liquids are generally designed for a range of 5-10 ft/s. Also, I would not design to exceed erosional velocity [v = c / sqrt(density) ]; where v is in ft/s and density in lb/ft3. The question is what is the value of c. Some fluids require 150...
Our company employs one drafter, one electrical designer and two civil designers. If the drafter and designers are not able to complete some drawings we would send them to a company with drafting labor in Vietnam. This contractor charged us $35/hr and we billed the client $60/hr. I was never...
Boiling fluids should always go up and condensing fluids down. As a chemical engineer, we do not specify the direction of flow on the data sheet. A mechanical engineer using HTRI or HX vendor would recommend the arrangement. We would just verify.
With respect to vertical baffles on the...
http://www.eng-tips.com/market.cfm
Students are not allowed to post homework problems in the Eng-Tips forums for the purpose of getting answers to their homework. This is considered cheating.
BigInch,
The answer to your first question is that the code is not within a module of the project, but within the userform itself. It does need to call Userform1_Click because the userform is itself the only user form.
For the second question, Please put the entire code so that I could more...
10815L,
A sketch would be very helpful to determine a good reply to your question. That is, will the water be pumped with a minimum flow return? Is it a horizontal or vertical vessel? Is there a weir? Will the oil exit the top or bottom?
~chemebabak
PMCap,
Your first question is the most important: " Are these calculators equally applicable to both restricting orifice plate and a flow orifice plate design?"
As you may know, a restricting orifice (RO) is a plate with a hole in it. The purpose of ROs is to limit flow. An FO is an RO that...
I am running Hysys 7.3 The dynamics assistant indicates that there is not error with simulation, however when I run it, I get an error "Unknown Pipe Diameter". I have specified the pipe diameter in a spreadsheet and I have tried to specify directly in the pipe object viewer. Where should I...
These are two good sources:
SPX Flow Technology White Paper
Google search results
Has scale been observed in your tanks?
If yes, then you probably should increase the dosing. Also, depending on your application you may consider a softener upstream of the CIP.
If no, then you may consider...