Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    @JedClampett, Not in the US and plus the contractor hasn't actually priced the work according to the complexity. Temporary work is always at the back of their mind when tendering. Otherwise they wouldn't get the job. I have yet to agree to proceed unless the contractor has given me free hand to...
  2. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    @EireChch, Just thinking out loud. The contractor did think about using sinking method to do but their concern is that if the structure they are sinking into the ground tilts too much then it will be end game for them. So maybe using an extra sheet pile cofferdam to help as a guide? I know this...
  3. cyphos168

    40 storey tower footing on PCC backfilled excavation.

    Just as a reference, the KL twin towers in Malaysia were built on cofferdams infilled with mass concrete down to quite a significant depth. You can Google the info. It was concreted down to competent strata. I believe it's limestone which is very common in KL.
  4. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    After much deliberation, I have decided to forego the cofferdam method of construction due to the poor ground condition. I have another alternative. Would doing the sinking method using sheet pile cofferdam as a guide be a better solution?
  5. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    @EireChch - I applied a FOS of 1.15 on gross passive pressures . And the contractor in a way is improving the soil on the passive side as well using driven piles to competent stratum. They will drive piles into the ground prior to setting up the cofferdam and excavating to formation level. The...
  6. cyphos168

    28 ft retaining wall

    In this situation I would go with contiguous bored pile walls. Might not be as costly as you think. 15' back space is only less than 5m which is no space at all to work with.
  7. cyphos168

    Retaining Wall Softwares

    Just to add on what I have posted above. I have since got myself Reward 2.8 from the UK to help with my cofferdam design. I read in the deepexcavation guidebook to actually have different software to analyse the same problem so I can compare the two results. Not going to argue with the expert. Lol!
  8. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    Hi all, Thanks for your input. After speaking to a local geotech expert and the software designer, I will be doing the following. FOS 1.2 for materials FOS 1.2 for earth pressure (active side) FOS 1.2 for moment, shear and prop forces I am pretty much covering all angles here when it comes...
  9. cyphos168

    Retaining Wall Softwares

    I am DeepEX user for a few years now. Slowly building up the modules as I went along. The software is very sophisticated as mentioned above. Maybe too sophisticated. LOL. Compared with say Wallap or Reward which I have used before, Deepex has tons of inputs which can be very daunting. As with...
  10. cyphos168

    Temporary Cofferdam design - What FOS should I use?

    Hi all. I am working on a cofferdam design. Since this is a temporary structure, I am wondering if I can use FOS=1 for soil analysis as well as structural design? Thanks.
  11. cyphos168

    Area of steel per m run of concrete slab

    Hi HTURKAK, Thanks for the response. I will post more info shortly but would like to just say the contour you see is the contour of top steel area in direction 1 or 2. Area of steel isn't that much different. Suffice to say the area of 1300mm2 per m run is the area of steel required for that...
  12. cyphos168

    Area of steel per m run of concrete slab

    Ok. I have been reading some topic on similar subject and the method of averaging the peak moment was mentioned several time. I till read through some of the resources mentioned.
  13. cyphos168

    Area of steel per m run of concrete slab

    Hi all, I have a problem I would like to have better understanding of. Its a flat slab design supported on columns. I am using Protastructure to analyse the slab by FE method. The result is showing the contour of the top hogging reinforcement near the column. Here is a snapshot of the top...
  14. cyphos168

    Calculating shear strength of concrete to concrete interface of a concrete plug in spun pile.

    Hi Hokie66, I have designed a spun pile which is basically inserted into a prebored hole in hard clay. Spun pile has no pile shoe hence my design by right should just take the area of the annulus of the spun pile to calculate base capacity. I would like to calculate the capacity of the base by...
  15. cyphos168

    Calculating shear strength of concrete to concrete interface of a concrete plug in spun pile.

    Hi, I need to calculate the capacity of a concrete plug in a spun pile to resist a push force. Tests have been conducted and written about it and published but these are actual tests to determine the shear stress at the interface by dividing the failure force kN against the surface area of the...
  16. cyphos168

    Wind load effect on Lattice Tower in MS Tower. Your thoughts.

    @WARose, Thanks for your input on this topic. My initial post and observations were referring to MSTower model. Not the Staadpro model. Sorry if my post may have been confusing. With Staadpro, the model is working as I would expect it to. In fact I have designed and successfully built a 27m...
  17. cyphos168

    Wind load effect on Lattice Tower in MS Tower. Your thoughts.

    @msquared48 Ya maybe there is one but I haven't found it yet. Haha... Will try to research some more on this. @hokie66 In the script I have assigned the correct member to each member and when I switched the toggle for 3D view, I can see the different member sizes. @WARose Please see attached...
  18. cyphos168

    Wind load effect on Lattice Tower in MS Tower. Your thoughts.

    Hi Guys, Thanks for your input on this matter. What I meant to say as far as item 1 is concern is that there is very little to no lateral deflection on the tower when I check again wind load combination. I mentioned vertical deflection as I am looking at the tower deflected shape on the screen...
  19. cyphos168

    Wind load effect on Lattice Tower in MS Tower. Your thoughts.

    Hi All, I am working on a lattice tower that is 65m tall and using MS Tower to design. I have created the load tower profile and generated the wind load combinations. I proceeded to analyse the tower and this is what I noticed. 1. Tower alone without any ancillaries, the deflection of the...
  20. cyphos168

    STAADPRO gives different results

    Hi Sye123, I went to Bentley download page but couldn't find any SSDD application. Can you direct me to the application? Thanks. Al
Back
Top