  1. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    ScottyUK - I'm in Asia. The washer is a Karcher HD 6/15C 1.150-601.0
  2. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    ScottyUK - That karcher was bought at USD1,500. We already bought a new Karcher for cleaning the A/C coils. I took the burnt one home for cleaning the cars but it seems that it will cost me much to rewind this so I bought a cheap USD100 washer. But still wanted to rewind this for curiosity (of...
  3. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Hi everyone. Here are some picture of the pump; New Skil (domestic series) as temporary replacement and Karcher (its a professional series here is the pump showing the regulator knob Pump piston The user manual of the karcher states; "Overflow valve with pressure switch - While...
  4. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Pete - Thanks again, your point is well noted. Trying to remove the old coils.....
  5. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Pete - by the way the winding is lap and I will rewind it also with lap Rhatcher - if the pressure regulator is not enough to compensate the pressure that will be produce due to the 20% increase in rpm, I'm planning to increase the hole of the nozzle by 20%? thus to release or balance the...
  6. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Guys thank you very much for all of you replies and comments. For now I will just buy a small washer while experimenting in this karcher motor. My plan is to rewound it following your comment to increase the wire size and reduce the no. of turns and see what will happen. Waross - yes it a...
  7. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Actually the motor coils are already burnt and rewinding is inevitable, rewinding it following the original specs and buying a transformer (230Vac to 276Vac) will too expensive and buying a new pressure washer will be more economical. Thanks for your replies, keep them coming.
  8. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    There is a knob for controlling the pressure so probably the pump can compensate the increase in the rpm due to 60Hz by adjusting this knob.
  9. Richard888

    Rewinding a Motor from 50Hz to 60Hz

    Hi guys I'm new here and in need of your professional advice. I have a burnt Karcher HD 6/15C pressure washer. The motor was a 230Vac single phase 50Hz 3.1kw we connect it to 230Vac 60Hz and the windings get burnt. Now I'd like to rewind it and I've been searching the net on how to convert it...