  1. enginerding

    1974 Concrete beam and joist schedule

    These responses are great! I had all three of these thoughts as possibilities, and I completely agree that this is a poor way of communicating the reinforcement. I could see jed's stance in that the short bars are only on the bottom for a short length, and I can see KootK's stance that the...
  2. enginerding

    1974 Concrete beam and joist schedule

    I am evaluating an existing floor for the weight of a nuclear medicine scanner. The structure is concrete joists and slab with concrete beams. One bar placement and bending diagram is provided that includes both joist and beam details. The typical top bars, bottom bars, and bent bars are...
  3. enginerding

    Old Flexicore Span Tables

    I have some flexicore info that shows 1020A-D43 (Flexicore designation 10R43) as having (3) 1/2" strands. phi-Mn = 59.82 ft-kips/unit. d=8.25". I have span tables for this without the topping from Calumet Flexicore in Hammond, IN dated September 7, 1978. I do not have span tables that include...
  4. enginerding

    Grouting deep masonry beam

    Thanks all for your input. It seems like we are split on whether to grout at once or one cell at a time. Maybe I will follow Fox's advice with the shear reinforcement so even if he is insistent on separate pours, we still have steel tying it all together. I will also follow up with the mason...
  5. enginerding

    Software that Designs Base Plates that are Supported on Leveling Nuts and not a Grout Pad

    HILTI's PROFIS software (free) used to do this. I have an older version of their software so I am not sure if it still includes cast-in-place anchors. I believe the biggest restriction for the cast-in-place anchor depth is 25" maximum. It does not design the weld to the tube. That's easy to do.
  6. enginerding

    Grouting deep masonry beam

    I have a project with a 40" deep (5 courses) reinforced masonry beam. The mason is proposing to build this and grout this one course at a time. He would build it like 5 bond beams on top of each other. I cannot find any notes in ACI 530 regarding grouting beams in multiple separate pours. Is...
  7. enginerding

    AWWA D-100-11 (Eqn 13-18)

    I think you are talking about Equation 13-18. I would note that the same equation in AWWA D100-05 contains Rc. I think it is fair to assume there is a typo in the 11 version.
  8. enginerding

    FOIA requests yields calculations

    This is actually a non-building structure. A competitor of my client has had difficulty getting approval on other similar structures in this municipality due to the structural plan reviewer rejecting their engineer's calculations. They did the FOIA request so that their engineer could see what...
  9. enginerding

    FOIA requests yields calculations

    Thank you all for your posts! A follow-up question: Should it make a difference whether the owner of the building in question did not give permission for the requester to see either the drawing or the calculations? In this case a third-party not associated with the owner requested structural...
  10. enginerding

    FOIA requests yields calculations

    Great response! I am located in Illinois too, so very appropriate. If you look at the enclosed link from the same website, it looks like these exemptions are not mandatory...
  11. enginerding

    FOIA requests yields calculations

    It is my opinion that the end product of a structural engineer is the construction drawings. While I have no problem submitting my calculations to a building official to help them with their due diligence while they do their plan reviews, I do not believe these to be a part of the public...
  12. enginerding

    Reinforced gypsum concrete

    I am working with an existing building with a reinforced gypsum concrete roof on bulb-tees on steel joists. I have downloaded the information from the gypsum association from this website. The 2006 IBC includes very little information in Section 1914. The old UBC has more info. The 1994 UBC...
  13. enginerding

    SPECIAL ANCHOR BOLT

    Use the same detail, but with stainless steel.
  14. enginerding

    66% Shelby tube recovery

    I am looking at a soil report that I need to use to design a foundation. Maybe I should first mention that about 75% of the text of the report discusses what was not done and what is not covered, and some information on local tort law. In the text of the report, there are three locations that...
  15. enginerding

    Three-wyth, unreinforced, freestanding wall

    The wall is brick-cmu-brick. It is 11-1/2" wide, which gives 3/8" between wythes as I figure it. No vertical reinforcement besides the dowels going only 16" high. To be honest, I don't think this wall could meet code as it is being 12' tall with no roof. Then by reducing the moment capacity...
  16. enginerding

    Three-wyth, unreinforced, freestanding wall

    I have a client who is dealing with an existing mechanical enclosure without a roof constructed of three-wythe masonry. His client wants to punch 4' wide x 28" tall holes near the bottom of this wall for additional ventilation. Building is only 5 years old, but there are no drawings for this...
  17. enginerding

    Biaxial compression in steel membrane structure

    It is a double curved membrane. Actually it is in reverse double curvature, which is the reason for the biaxial compression. By reverse curvature I mean that the radius of the cross section is outside the section. Picture a single pedestal steel water tower, for example. The transition...
  18. enginerding

    Biaxial compression in steel membrane structure

    Does anyone have a good reference for designing for biaxial compression in steel plates for water storage structures? AWWA D100 provides membrane buckling capacities where the stresses are uniaxial compression or compression with hoop tension, but states that biaxial compression is beyond the...
  19. enginerding

    Steel structure for digital billboard on 120 year old wood balloon-framed building

    Thanks guys. I apparently have the same weird phobia. Supporting the thing independently was my original recommendation. I completely agree with the lateral load issues too - even in the walls. The client is telling me it shouldn't be an issue since the existing billboard has been there...
Back