Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  • Users: amaidj
  • Order by date
  1. amaidj

    Minimum Bearing of Ground Beam

    Hi, can anyone suggest me any minimum bearing reference from any code for prestressed ground beams like the one attached? Thanks a million.http://files.engineering.com/getfile.aspx?folder=e09fda4b-3bad-40dd-9c77-ba77ff1211c0&file=aaa.png
  2. amaidj

    Shear Reinforcement Calculation between walls

    Things are not that complicated, its simple concrete connection, now this concrete connection has several types but it doesnt matter because once u have calculated capacities u can decide which type you choose.
  3. amaidj

    Shear Reinforcement Calculation between walls

    the type of connection doesn't matter, its just a calculation of shear strength of concrete cast at different times, now depending upon the strength there i can choose the connection, but i am looking if someone has done such detail/calculation before so to share, as what i am confusion is; i...
  4. amaidj

    Shear Reinforcement Calculation between walls

    it would have been much better to comeup with the example i asked for rather then suggestion. i know the calculations and i have mine, I only need to double check with any sample or example to be sure which is why i asked but anyways, thanks for ur suggestion!
  5. amaidj

    Shear Reinforcement Calculation between walls

    Hi, i have designed Precast wall panel now i need to design horizontal connection of two walls, could anyone suggest me any method or example? i need to follow Eurocode. Any Example would be great. Regards,
  6. amaidj

    Tekla Structural Designer

    I need to apply Line and point loads(vertical loads) on wall, but i dont know how to do that. if apply an element on top of wall and apply loads over it, it gives me validation error, similarly with if i define a very small beam on top of wall it gives me the similar error. i dont know how else...
  7. amaidj

    Tekla Structural Designer

    out there anyone use TEkla Structural Designer software?? if yes please let me know i have related question. Thanks a million.
  8. amaidj

    Prestressed Ground Beams

    i have just figured out my sections are overstressed :(
  9. amaidj

    Prestressed Ground Beams

    @Ingenuity, do you mean my fci suppose to be 40Mpa at transfer? and yes, the product is produced similar to hollowcore.
  10. amaidj

    Prestressed Ground Beams

    @Ingenuity, its 7mm dia wire of area 38.5mm2 i have 3 wires at 27mm from bottom then one at 50 mm at bottom and them one at 75mm from bottom these are ground beams use for flooring. the section depth is 225mm i think as per my understanding the stress applied is too much for this small secrion...
  11. amaidj

    Prestressed Ground Beams

    Please take a look of the pictures attached, these are prestressed ground beams, i used 5-7dia prestressed wires. your comments as per ur understanding related to this failure will be appreciated...
  12. amaidj

    Recommendation for Prestressed/Precast Slabs and Beam Design Software

    Please could you guys recommend handy software to design Prestressed/precast slabs and beams that supports Eurocode/British Standard Code.
  13. amaidj

    Recommendation for Prestressed/Precast Slabs and Beam Design Software

    Recommendation for Prestressed/Precast Slabs and Beam Design Software
  14. amaidj

    Steel Connection Design Practice Code

    Like Aisc which code is used in Europe to design Steel structures/Connections?
  15. amaidj

    Slender Span

    this beam is precast concrete beam this beam is supporting 320 HCS having wearhouse loading. i have provided Beam end restrained by introducing insitu column and extended my beam reinforcement into column. Now what do you guys think?
  16. amaidj

    Slender Span

    Hi, if i have beam which is slender so basically width to depth ratio is not as specify in Code which makes it slender, which means it might have secondary effects but its still a beam, what kind of secondary effects am i dealing here with? and i am ensuring it takes torsion and making sure to...
  17. amaidj

    Designing an L beam?

    How do you mean? when you say you have design beam as L-Beam and if you have considered L-Part as half of slab then ofc you dont need to design but i am not sure if you can do that? as in this case its quite simple u need to design beam as rectangle and design slab as simply supported thats all...
  18. amaidj

    What is the difference between BS 8110-1:1997 and BS EN 1992-1-1:2004+A1:2014

    What is the difference between BS 8110-1:1997 and BS EN 1992-1-1:2004+A1:2014 can someone explain me if BS and EN are the same code? if not then what is BS EN means? every time its written together as a reference of code like one mention above? Thanks,
  19. amaidj

    Lateral Propping for Precast Slender Beams

    @Warose, my span is 6 meters but depth is around 1.88 meters and width is 300mm now my concern is considering depth of beam do i need lateral propping? Regards
Back
Top