  1. theshearstud

    UPLIFT ON METAL ROOF DECK

    The allowable load tables published are for gravity load only. I reached out to my Vulcraft rep a while back and asked about his. Your rep should be able to provide you with uplift load tables if you ask.
  2. theshearstud

    Predicting Building Drift Accelerations under Wind for Mid - High Rise

    Is anyone aware of a standard/document that is useful when trying to predict building drift accelerations? I couldn't find anything in ASCE 7. I would imagine the procedure would be similar to evaluating the response of a spring-damper system subject to a triangular pulse.
  3. theshearstud

    When to consider laterally supported

    Not trying to get caught in the technical weeds, but aren't those buckling equations derived assuming torsional fixity at the supports? So all this is assuming that you have beams framing into the ends of your dropped beam (which would provide some level of torsional restraint), correct?.
  4. theshearstud

    support condition of concrete beam connected to a shear wall

    Hopefully not too late! You have your beams modeled as "outriggers". For a 8 story building, this is likely INCORRECT. You need to pin the beams that frame into the shear walls. By having these beams fixed, you are greatly increasing the stiffness of your structure (along with the shears and...
  5. theshearstud

    AISC DG 11 _ Sensitive Equipment

    @Hokie93 - I'll give that a shot. Thanks.
  6. theshearstud

    Modeling walls

    I may need a little more information to attempt an answer. When you say the fixture will "hold" a building, are you meaning that the building will sit on it? What do you mean by "composite effect" of the building? Is the building concrete? What are you trying to accomplish by supporting this...
  7. theshearstud

    AISC DG 11 _ Sensitive Equipment

    Your point makes sense. I could not find elaboration on why RMS is used. In the below doc. written by Ungar (who seems to be one of the top experts in this field), he uses RMS. http://www.sandv.com/downloads/0709unga.pdf
  8. theshearstud

    AISC DG 11 _ Sensitive Equipment

    Does anybody know why DG 11_Sensitive Equipment uses peak velocity when checking floor vibrations while the majority of the related literature state that RMS is more appropriate?
  9. theshearstud

    Slab Supported By Beams

    Do not restrain your shell element for these conditions.
  10. theshearstud

    Slab Supported By Beams

    Might be too late...but yes something is wrong. It seems as though you have not meshed your wall/slab. For this type of model, I would recommend the following: 1. Select Wall (Shell Element) -> Edit Menu -> Divide Area 2. Select Slab (Shell Element) -> Edit Menu -> Divide Area (be sure to use...
  11. theshearstud

    Properly Modelling the umbraced length for a steel member for lateral torsional buckling

    Selected members only. To check this, after you assign your brace points: run the analysis and steel design check (Design tab -> Steel design). After, right click on your member -> Detailed (report button...it doesn't matter which load combination is chosen). The report should specify what...
  12. theshearstud

    Properly Modelling the umbraced length for a steel member for lateral torsional buckling

    Select Member --> Design Tab --> Lateral Bracing --> User Specify
  13. theshearstud

    Wood Analyses using Sap

    http://www.fpl.fs.fed.us/products/publications/several_pubs.php?grouping_id=100&header_id=p
  14. theshearstud

    Area mesh and linear analysis modes on sap2000 v18

    From what I remember: When you draw an area element with four nodes only, the program will not automatically "auto mesh" your element (assuming you have not assigning an auto mesh. When you draw an element with more than 5 nodes, the program will mesh your element, whether your assign a...
  15. theshearstud

    Equivalent or notional horizontal force??

    Both used to account for imperfections only
  16. theshearstud

    Equivalent or notional horizontal force??

    I believe they are the same thing. AISC uses the term "notional load". Eurocode uses the term "Equivalent Horizontal Force".
  17. theshearstud

    Vertical Reinforcement of Coupled Shear Walls

    This is understanding that tension in the wall may control....just talking about minimum reinforcement here.