Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: nicam
  • Order by date
  1. nicam

    Two-way or one-way concrete slab system?

    What are the support conditions? and where are the supports?
  2. nicam

    Point load on suspended concrete slab

    The loads are quite small, what is the slab thickness, span etc. you should just call a local engineer. we don't work out such stuff for people asking on an internet forum. as you mentioned kg's I assume you're from Australia?
  3. nicam

    Structural Loads and Analysis Programs

    TX Structural i think you are a bit hush on software, sure the garbage in garbage out saying is true, but we engineers have had many years of training to understand the garbage in garbage out theory. The don't trust software argument is valid for an untest new software or untrained people. How...
  4. nicam

    Robot SA software RC beam design

    Hi leeo123, So I assume you use 1.2DL + 1.5LL for ultimate and 2.4DL + 1.26LL for service. if so you don't get the software to check strength when your using a service combination. only check deflection. So the ultimate combo for checking strength i.e designing the bars and use the service...
  5. nicam

    effective length of Cantilever

    Hi just an update. Attached photo of my awning! See BAretired the structure is stable! http://files.engineering.com/getfile.aspx?folder=d9571073-3dcf-4935-8169-c3b380684985&file=P5240014.JPG
  6. nicam

    Concrete Software

    Hokie66, I perfer Inducta (slabs, RC building & PT3D) much better in my opinion.
  7. nicam

    effective length of Cantilever

    only because I wasn't sure if you need to consider the whole cantilever length or just the segment lengths. When designing simple beams I would use the segment length between the restraints but thought the rules are different for cantilevers.
  8. nicam

    effective length of Cantilever

    The structure is stable the columns are fully fixed, that's how space gass shows full fixity on the 3D render output. attached is the normal screen view showing bending moments. http://files.engineering.com/getfile.aspx?folder=7e1ca5e1-956a-4e6d-afc9-977d4698d4c5&file=BM.jpg
  9. nicam

    effective length of Cantilever

    Hi I'm currently designing a steel awning structure and I'm trying to determine the effective bending length, AS4100 has 3 k factors kt, kl & kr for segment lengths. I know that with cantilever beams kt = 1.1, kl = 2 & kr = 1 for unrestrained members. my awning is attached. the outrigger...
  10. nicam

    Class 2 formwork finish

    Thanks, if the chairs are still visible would you still consider it a class 2 finish?
  11. nicam

    Class 2 formwork finish

    Had a job here that the architect specified class 2 formwork finish. The builder is now saying the plastic reinforcement chairs are showing up through the concrete finish. any ideas on how to fix this?
  12. nicam

    Wide Span Portal frame.

    Limit state. Deflection? can't remember but I'm pretty sure We didn't exceed the limits! My boss did the original design, he asked me to verify the design. I think the portals were less then 9m c/c I'll check the model again and come back to you.
  13. nicam

    Wide Span Portal frame.

    no problem! I've designed 55m portals with standard welded beam sections. (building is still standing after 1 year!!)
  14. nicam

    Factored load or un-factored load in deflection calcs?

    In Australia under AS3600 we normally use factored loads for concrete 2.4G + 1.26Q
  15. nicam

    design connections between RHS to existing UB column

    I would suggest you get a structural engineer to give you a detail.
  16. nicam

    Residential Elevator Loading

    The lift manufacturer should give you all the loads
  17. nicam

    sand foundations

    Thanks for the comments, We asked for a geotech but the client wasn't willing to pay for one despite our insistance. I don't understand why the client is not short of money living in a very well to do area and his two mercedes, but to spend a bit of money on geotech..too much!
  18. nicam

    sand foundations

    Hi, I've desigened an extension to a house (a balcony structure) and we've ask to confirm the foundation type. We asked the builder to excavate against the existing house footings. the inspection revealed the house is bearing on sand. The house is very old two storeys and showed no signs of...
  19. nicam

    Determine load rating of a lifting beam

    I don't mean to be rude but do you have any ideas on how to start this?
Back