Greetings everyone
I was doing structural analysis of simple problem having bonded connection using MPC formulation having asymmetric behavior but I am keep on getting following error
" one or more MPC contact region or remote boundary condition may have conflicts with other applied boundary...
greetings everyone
can anyone explain me working of solenoid operated relief valve???? (picture of which is attached, valve is marked 18)
i know it is used for cutting off the pump when pressure starts building. but not able to grab the concept how it works???
thanx in advance...
Greetings everyone
first of all let me give a overview of machine that we manufacture based on which this problem is based
we manufacture this hydraulic press which presses powdered coal to make it in a cake form.
my question is when this hydraulic press puts pressure on powdered coal...
thanks for showing interest
weight of plate 21 tonne
weight of block 34 tonne
plate M.S.
floor brick
block coal
how to calculate U1 and u2???
i know it seems stupid but is there any software that can verify this?? like can it be checked in any analysis software???
and we dont have any...
Hello everyone
Said "structure" will be locked by hydraulic cylinder from sides
That way structure will stop the Coal Block from moving where as its wheel will allow it to move with plate
Thanks everyone for their comments
I will make my calculation as instructed by LittleInch
If someone have anything to add please let me know, that will be really helpful.
above mentioned system is already implemented.
What we do is we stop the block by structure whose wheels rests on plate.
when plate is pulled structure stops the block from moving along the plate. while structure rolls on plate
We cannt incline the plate due to various constraint.
As the cake...
Sure IRstuff
We manufacture machinery used in Hard coke oven plant.
and this plate carry compressed cake which is placed inside coke oven and after that plate is pulled outside leaving cake inside coke oven.
We wanted to calculate motor required to pull this plate outside and also chain that...
Hiii
I need to calculate force required(F1) to pull the plate out with block leaving behind on Floor(to eventually calculate motor HP).
If
W1 is Weight of block
W2 is weight of plate
Cf1 is Coefficient of friction between block and plate
Cf2 is coefficient of friction between plate and floor...
Greetings
Can any one tell in what cases which formulation method should be used for bonded connection and no separation (MPC or Pure penalty) ???
Also which formulation method to use for frictional, friction less and rough connection???
Thanks
one last thing orel.
Do i need to fix my model or i need to make some other changes to get rid of such error??
what according to you i did wrong to get such error???
i can see many contact region showing as far open and marked as red in initial information.
I suppose if i can fix it i can get rid of this error.
thanx a lot orel.