Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: L0k
  • Order by date
  1. L0k

    "Punch sampler" or "Punch boring"

    they want to know the subsoil by drilling
  2. L0k

    Swell Vs Heave

    Agreed with the above comments as my understanding are: Heave is happening due to the external loading, say you place an embankment you will get an amount of heaving. Swell is happening due to the inner substances influencing the soil grain behaviour especially in OCC soils.
  3. L0k

    Piles on Organic Silty Sand

    The pile will rely on end bearing plus the skin of non organic sandy layer, disregard the organic loose silty sand skin friction. A corrosion paint shall be applied on the steel pile section to protect corrosion at the 20 feet of organic silty sand layer. Bored pile is not recommended unless a...
  4. L0k

    Vibrating wire piezometer dry

    Place the piezometer in the water tank covered by geotextile and sandy gravel to avoid clogging.
  5. L0k

    Rule of Thumb for Mobilizing Full Capacity During PDA Testing?

    Thanks, MTNClimber Based on your data I calculated the ultimate pile capacity are 640kips and 740kips for HP12x74 and HP14x89 respectively. I assumed the rebound value 0.6" and the hammer efficiency is 85%
  6. L0k

    Rule of Thumb for Mobilizing Full Capacity During PDA Testing?

    Hi MTNClimber, I am interested to your experience in PDA & static loading test. Can you inform us some information on the static load tested piles such as: the hammer weight, falling height, final set & rebound value?
  7. L0k

    Soil test calculation.. Part

    That is very simple, Karegowd. It needs weights. - place the proving ring in the flat bench - place the weight load on top of the proving ring & read the dial - do the above step several times up to the maximum proving ring capacity, but not to exceed it. - draw the curve loads vs dial readings...
  8. L0k

    Executing a borehole adjacent to Bored pile

    If the bored pile is concreted, 1 m away is a fair distance to do a borehole. A temporary casing is a must in a silty SAND layer to avoid caving in. Casing installation should be pushed and no allowance for vibration that creating a loose sand and consume a lot of concrete.
  9. L0k

    Settlement calculation for strip footing

    Immediate settlement formula is based on the elastic condition and one of them was given by Schmertmann. This may be an option to consider.
  10. L0k

    Gabion for stream protection

    Thanks dik for the practical solution. Thanks avscorreia for the excellent Links.
  11. L0k

    Gabion for stream protection

    Hi... could you help me to give a simple design for a gabion wall to protect the river bank? how to calculate the hydraulic force against the gabion to include in the stability analysis? Other issues are to increase bearing capacity and secondly to protect the footing base against scouring. Thanks
  12. L0k

    Tension Pile Load Test

    mbilal89, I think your testing is against the ASTM recommendations that the reference beams shall be supported at a clear distance of at least 5 times the test pile diameter. The picture shows that the supported reference beams are inside the cracking zone area. So the maximum displacement of...
  13. L0k

    Asking for recommendation for foundation design

    I prefer to install 14m long wickdrain or sanddrain then preloading.
  14. L0k

    Overloading existing piles

    Hi Okiryu In my gut feeling with additional 20%load will give a FOS 2.5. In the existing building the piles had been no excess pore pressure anymore, it means the strength is higher (x%) than the strength during installment.
  15. L0k

    Calculation for Driven Pile

    Hi Hamza In finding the pile capacity of a driven pile, I use a dynamic formula i.e. Hiley formula, so you have to know several parameter such as: the hammer weight, falling height, hammer efficiency, setting and rebound value. It will be useful if you can conduct a pile loading test.
  16. L0k

    Immediate and Consolidation Settlement

    I think mv is not related with immediate settlement. Immediate settlement has on the way when you place the porous stone, consolidation cap and load hanger while the dial gauge is not install yet.
  17. L0k

    Bearing capacity of a high plasticity silt (MH)

    Hi Atros The undisturbed sample will create the the undrained Su > the remoulded strength, it was not happening in your strength where Su=0.32kg/cm2 < Sr=0.89kg/cm2. This showed that your sample is having a certain disturbance, that's why I prefer the in-situ strength. I cannot calculate your...
  18. L0k

    Pwp dissipation using CPT

    Hi Pelelo This is the pore pressure data I use for liquefaction analysis.http://files.engineering.com/getfile.aspx?folder=2d411311-f942-4fbe-bb0d-a46ed44db88a&file=0.13g.JPG
  19. L0k

    Bearing capacity of a high plasticity silt (MH)

    Hi Atros What is your footing width? If the fluctuation of ground water depth is outside of the failure criteria, the undrained parameters may be applicable. Since the soil is MH- a high plasticity silt, an undrained insitu test such as shear vane test may be considered as a design parameter. I...
  20. L0k

    Sinkhole in an open field.

    my experience in grouting the limestone and basalt layer was required lots of grouting material, si it is required a detail investigation.